高级检索
当前位置: 首页 > 详情页

腔内传感器法食管运动功能试验研究-85名正常人食管下括约肌功能试验结果分析

A STUDY ON THE ESOPHAGEAL FUNCTION TEST BY MEANS OF TRANSDUCER IN ESOPHAGEAL CAVITY IN 85 NORMAL PERSONS

文献详情

资源类型:

收录情况: ◇ 中华系列

单位: [1]北京友谊医院内科
出处:
ISSN:

摘要:
A new method for esophageal function test by means of trasducer in esophageal cavity is introduced and the result of esophageal funcion test in 85 normal subjects is reported. Three methods namely, SPT, RPT and location method are discussed. Among them, SPT method was the most accurate one in detecting the length and location of LES, RPT mthod was not affected by respiration. Location method could measure the pressure at any point in esophageal cavity. The intraesophageal pressure was found the highest by RPT method. Au The pressures measured by the 3 methods showed on difference in sex bvt there was difference with age by RPT and location method. The barrier pressure was 9.92 ± 5.96 mmHg. The length of LES was 4.02 ± 0.95 cm. The coordination between the relax of LES and movement of esophageal body and stomach during swallow was studied. The results revealed that the relax, contraction and closure of LES are necessary for transfering food in esophageal cavity under normal condition. Normally, it needs more than 0.2 second for relax of LES during swallow.

语种:
第一作者:
第一作者单位: [1]北京友谊医院内科
推荐引用方式(GB/T 7714):

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题