高级检索
当前位置: 首页 > 详情页

Accuracy of two orthodontic mini-implant templates in the infrazygomatic crest zone: a prospective cohort study.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Stomatology, Beijing Xuanwu TCM Hospital, No. 13 Wan'ming Road, Xicheng District, Beijing, China. [2]Department of Stomatology, Beijing Friendship Hospital, Capital Medical University, No. 95 Yong'an Road, Xicheng District, Beijing, China. [3]Department of Stomatology, Beijing Friendship Hospital, Capital Medical University, No. 95 Yong'an Road, Xicheng District, Beijing, China. huangxf1998@163.com.
出处:

摘要:
In the clinic, most computer-aided design and manufacturing orthodontic mini-implant guides are suitable for the position between the tooth roots, and few templates are designed and used for the infrazygomatic crest zone. In this study, we took into account the structure of the infrazygomatic crest and 3D printing technology, developed two kinds of templates, and evaluated their clinical effects.Seventeen patients who accepted 30 mini-implant insertions in the infrazygomatic crest were selected. According to different implantation methods, three groups were divided. In Groups A and B, the mini-implants were positioned with an A-type or B-type template designed by EXOCAD software. In Group C, the mini-implants were inserted by an experienced orthodontist without any guides. We simulate the bucco-palatal, mesio-distal, and vertical head positions in the Segma implant guide software and measure the deviation from the virtual design position of the mini-implant. The linear deviation of the mini-implant tip and cap and the angular deviation of the long axis of the mini-implant in the bucco-palatal direction, mesio-distal direction, and vertical direction were also measured. The results were statistically analysed by SPSS software.The deviations of Group A and Group C's miniscrew cap in the bucco-palatal direction, Group A and Group B, Group A and Group C's miniscrew tip in the mesio-distal direction, and Group B and Group C's miniscrew tip and cap in the vertical direction were statistically significant (P < 0.05). There was a significant difference in the deviations of Group A and Group C's miniscrew tip and cap in the vertical direction (P < 0.01).In the vertical direction, the accuracy of implantation with the template is higher than that of the traditional method without the template to avoid piercing the maxillary sinus mucosa in the infrazygomatic crest zone.© 2022. The Author(s).

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 牙科与口腔外科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 牙科与口腔外科
JCR分区:
出版当年[2020]版:
Q2 DENTISTRY, ORAL SURGERY & MEDICINE
最新[2023]版:
Q1 DENTISTRY, ORAL SURGERY & MEDICINE

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Department of Stomatology, Beijing Xuanwu TCM Hospital, No. 13 Wan'ming Road, Xicheng District, Beijing, China. [2]Department of Stomatology, Beijing Friendship Hospital, Capital Medical University, No. 95 Yong'an Road, Xicheng District, Beijing, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)