A point-of-care microfluidic channel-based device for rapid and direct detection of fibrinogen in whole blood.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Institute of Health Service and Transfusion Medicine, Beijing 100850, P. R. China. lovechina1980@163.com. [2]BGI College, Zhengzhou University, Henan, 450001, P. R. China. [3]Anbio (Xiamen) Biotechnology Co., Ltd, Xiamen, Fujian Province, 361028, P. R. China. [4]Center of Clinical Laboratory, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, P. R. China. [5]Suzhou Institute of Biomedical Engineering and Technology (SIBET), Chinese Academy of Sciences, Suzhou, Jiangsu Province, 215163, P. R. China. wangdm@sibet.ac.cn.
出处:
ISSN:

摘要:
Hemorrhage is the leading cause of preventable death in civilian and battlefield traumatic injuries. Patients with severe traumatic hemorrhagic shock are more likely to be deficient in fibrinogen than those with other coagulation factors, and hypofibrinogenemia is an independent risk factor for mortality. Thus, rapid detection of fibrinogen levels is of great importance in these patients during damage control resuscitation. Plasma is used as an analyte in fibrinogen detection, which restricts the use of existing devices in emergencies. To meet the needs of on-site detection, we developed a point-of-care microfluidic channel-based device for direct measurement of fibrinogen concentration in whole blood. In our method, thrombin is dispersed on a reaction strip to initiate conversion of fibrinogen to fibrin. The permeability of the resulting blood clots depends on the fibrinogen level. A hydrophobic plastic protection flake between the reaction strip and a wicking strip is then removed to allow flow of unclotted blood. The rate of blood flow along the wicking strip was inversely related to the fibrinogen concentration. The whole process could be completed in as fast as 5 minutes for a whole blood sample size of 150 μL, and yielded accurate results ranging from 0 to 4 g L-1, which were unaffected by Ca2+, blood lipids, hematocrit, warfarin and tissue plasminogen activators (tPAs). Results using clinical whole blood samples were also highly consistent with those using an automatic coagulation analyzer, yielding a Pearson correlation coefficient of up to 0.919. This approach has potential for allowing rapid diagnosis of fibrinogen concentration in critically ill bleeding patients in different settings, thus helping to judge the suitability of fibrinogen replacement therapy (FRT) in cases of emergency bleeding and in patients at risk of thrombosis due to hyperfibrinogenemia.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 1 区 工程技术
小类 | 1 区 生化研究方法 1 区 分析化学 1 区 仪器仪表 2 区 化学综合 2 区 纳米科技
最新[2025]版:
大类 | 2 区 工程技术
小类 | 1 区 生化研究方法 1 区 分析化学 2 区 化学:综合 2 区 仪器仪表 3 区 纳米科技
JCR分区:
出版当年[2020]版:
Q1 BIOCHEMICAL RESEARCH METHODS Q1 CHEMISTRY, MULTIDISCIPLINARY Q1 INSTRUMENTS & INSTRUMENTATION Q1 CHEMISTRY, ANALYTICAL Q2 NANOSCIENCE & NANOTECHNOLOGY
最新[2024]版:
Q1 BIOCHEMICAL RESEARCH METHODS Q1 CHEMISTRY, ANALYTICAL Q1 INSTRUMENTS & INSTRUMENTATION Q2 CHEMISTRY, MULTIDISCIPLINARY Q2 NANOSCIENCE & NANOTECHNOLOGY

影响因子: 最新[2024版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Institute of Health Service and Transfusion Medicine, Beijing 100850, P. R. China. lovechina1980@163.com. [2]BGI College, Zhengzhou University, Henan, 450001, P. R. China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:819 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)