Motion artefact reduction in coronary CT angiography images with a deep learning method

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No.95 Yongan Road, Xicheng District, Beijing, People’s Republic of China [2]Philips Healthcare, Beijing, China [3]Shukun (Beijing) Technology CompanyLtd, Beijing, People’s Republic of China
出处:

关键词: Coronary CT angiography Motion artefacts Artifcial intelligence Deep learnings

摘要:
The aim of this study was to investigate the ability of a pixel-to-pixel generative adversarial network (GAN) to remove motion artefacts in coronary CT angiography (CCTA) images.Ninety-seven patients who underwent single-cardiac-cycle multiphase CCTA were retrospectively included in the study, and raw CCTA images and SnapShot Freeze (SSF) CCTA images were acquired. The right coronary artery (RCA) was investigated because its motion artefacts are the most prominent among the artefacts of all coronary arteries. The acquired data were divided into a training dataset of 40 patients, a verification dataset of 30 patients and a test dataset of 27 patients. A pixel-to-pixel GAN was trained to generate improved CCTA images from the raw CCTA imaging data using SSF CCTA images as targets. The GAN's ability to remove motion artefacts was evaluated by the structural similarity (SSIM), Dice similarity coefficient (DSC) and circularity index. Furthermore, the image quality was visually assessed by two radiologists.The circularity was significantly higher for the GAN-generated images than for the raw images of the RCA (0.82 ± 0.07 vs. 0.74 ± 0.11, p < 0.001), and there was no significant difference between the GAN-generated images and SSF images (0.82 ± 0.07 vs. 0.82 ± 0.06, p = 0.96). Furthermore, the GAN-generated images achieved the SSIM of 0.87 ± 0.06, significantly better than those of the raw images 0.83 ± 0.08 (p < 0.001). The results for the DSC showed that the overlap between the GAN-generated and SSF images was significantly higher than the overlap between the GAN-generated and raw images (0.84 ± 0.08 vs. 0.78 ± 0.11, p < 0.001). The motion artefact scores of the GAN-generated CCTA images of the pRCA and mRCA were significantly higher than those of the raw CCTA images (3 [4-3] vs 4 [5-4], p = 0.022; 3 [3-2] vs 5[5-4], p < 0.001).A GAN can significantly reduce the motion artefacts in CCTA images of the middle segment of the RCA and has the potential to act as a new method to remove motion artefacts in coronary CCTA images.© 2022. The Author(s).

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2020]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, No.95 Yongan Road, Xicheng District, Beijing, People’s Republic of China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)