高级检索
当前位置: 首页 > 详情页

Accuracy of magnetic resonance imaging in defining dentate line in anal fistula

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]China Acad Chinese Med Sci, Xiyuan Hosp, Dept Radiol, 1 Rd Xiyuancaochang, Beijing 100091, Peoples R China [2]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing, Peoples R China
出处:
ISSN:

关键词: Anal canal Dentate line Magnetic resonance imaging Anal fistula

摘要:
Purpose To retrospectively assess the accuracy of magnetic resonance imaging (MRI) in defining dentate line in anal fistula. Materials and methods Seventy patients with anal fistulas were assessed by dynamic contrast-enhanced MRI. The distance from the dentate line to the anal verge for all patients was measured by MRI. To mitigate interference, 35 patients with anal fistulas whose internal openings were located on the dentate line were excluded from this study. Two observers independently judged the positional relationship between the internal opening and the MRI-defined dentate line, and compared with the results observed by surgeon to assess the accuracy. Results The distance between the MRI-defined dentate line and the anal verge depended on the location of the internal opening and the morphology of the anal canal mucosa. The distance based on the location the internal opening and the morphology of the anal canal mucosa was 18.2 +/- 8.1 mm and 20.0 +/- 5.3 mm on oblique coronal T2WI, respectively. Compared with the results observed by the surgeon, the accuracy of evaluating the positional relationship between the internal opening and the dentate line from the morphology of the anal canal mucosa on MRI exceeded 89.9%. Taking 18.2-20.0 mm as the distance between the dentate line and the anal verge on the MRI image, the accuracy of evaluating the relationship between the position of the internal opening and the dentate line was over 85.7%. Considering both the dentate line and the anal canal mucosa, the accuracy of evaluating the relationship between the internal opening and the dentate line was over 91.5%. The results of MRI-defined dentate line were in good agreement with the results of intraoperative surgeon evaluation, and the kappa values were 0.70, 0.63, and 0.78, respectively. Conclusion MRI has high accuracy in defining the dentate line in anal fistulas.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2020]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]China Acad Chinese Med Sci, Xiyuan Hosp, Dept Radiol, 1 Rd Xiyuancaochang, Beijing 100091, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:819 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)