高级检索
当前位置: 首页 > 详情页

Assessing Liver Hemodynamics in Children With Cholestatic Cirrhosis by Use of Dual-Energy Spectral CT

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Beijing Friendship Hospital,Capital Medical University, 95 Yong’an Rd, XichengDistrict, Beijing, China, 100050. [2]Department of Radiology, Hospital of Shunyi District,Beijing, China. [3]Department of Liver Transplantation, Beijing FriendshipHospital, Capital Medical University, Beijing, China.
出处:
ISSN:

关键词: biliary atresia children cirrhosis dual-energy CT hemodynamics liver

摘要:
OBJECTIVE. The purpose of this study was to evaluate the value of dual-energy CT (DECT) in assessing liver hemodynamics in children with cholestatic cirrhosis. MATERIALS AND METHODS. The cases of 60 children with cholestatic cirrhosis (study group) and 15 children with inherited metabolic diseases but normal liver function (control group) were retrospectively evaluated. Enhanced CT scans were obtained in spectral imaging mode. Iodine concentration (IC) of hepatic parenchyma in the arterial phase (ICA) and portal venous phase (ICP) was measured on iodine-water material decomposition images. The hepatic arterial iodine fraction (AIF) was calculated as: AIF = ICA / ICP, The ICA, ICP and AIF of children in the control and study groups were analyzed by one-way ANOVA and post hoc test with Bonferroni correction. The radiation dose was recorded. RESULTS. There were differences in ICA and AIF between the control and study groups. The values in patients in the Child-Pugh class C group were the highest and those in the control group the lowest (p < 0.05). Statistically significant differences in ICP were not found (p> 0.05). Specifically, the multiple comparison results indicated that there were differences in both ICA and AIF in most of the groups (p < 0.05). The volume CT dose index value for all patients was the same at 10.14 mGy for each enhanced phase, and the total dose-length product varied between 402.68 and 679.18 mGy-cm. CONCLUSION. ICA and AIF obtained at dual-energy CT can be used as semiquantitative indicators to evaluate the liver hemodynamics of children with cholestatic cirrhosis.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2018版] 出版当年五年平均[2014-2018] 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Department of Radiology, Beijing Friendship Hospital,Capital Medical University, 95 Yong’an Rd, XichengDistrict, Beijing, China, 100050. [2]Department of Radiology, Hospital of Shunyi District,Beijing, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)