Clinical Study on Safety and Efficacy of Microwave Ablation for Primary Hyperparathyroidism

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Interventional Ultrasound, China-Japan Friendship Hospital, Beijing, China
出处:
ISSN:

关键词: Microwave ablation Primary hyperparathyroidism Intact parathyroid hormone

摘要:
Objective: To evaluate the safety, feasibility, and efficacy of microwave ablation (MWA) for the treatment of primary hyperparathyroidism (PHPT). Materials and Methods: This study enrolled 67 PHPT patients (22 men, 45 women; mean age, 56.0 +/- 16.3 years; range, 18-83 years) from January 2015 to December 2018. The laboratory data, including the serum intact parathyroid hormone (iPTH), calcium, phosphorus, and alkaline phosphatase (ALP) levels, were evaluated before MWA and again 2 hours, 1 day, 7 days, 1 month, 3 months, 6 months, 12 months, 18 months, and 24 months after. Results: Complete ablation was achieved with all 72 hyperplastic parathyroid glands found on the 67 patients enrolled, 64 of whom were treated in one session and 3 were treated over two sessions. The technical success rate was 100%. The median follow-up time was 13.6 months (range, 10.0-31.1 months). The clinical success rate was 89.4%. The volume reduction rate was 79.4% at 6 months. Compared to pre-MWA, the serum iPTH, calcium, phosphorus, and ALP levels had significantly improved 6 months post-MWA (iPTH, 157.3 pg/mL vs. 39.2 pg/mL; calcium, 2.75 +/- 0.25 mmol/L vs. 2.34 +/- 0.15 mmol/L; phosphorus, 0.86 +/- 0.20 mmol/L vs. 1.12 +/- 0.22 mmol/L; ALP, 79 U/L vs. 54 U/L, respectively; all, p < 0.01). Hoarseness was a major complication in 4 patients (6.0%), but it improved spontaneously within 2-3 months. Conclusion: MWA is safe, feasible, and effective for the treatment of PHPT.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2018版] 出版当年五年平均[2014-2018] 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Department of Interventional Ultrasound, China-Japan Friendship Hospital, Beijing, China
通讯作者:
通讯机构: [1]Department of Interventional Ultrasound, China-Japan Friendship Hospital, Beijing, China [*1]Department of Interventional Ultrasound, China-Japan Friendship Hospital, No. 2 Ying-hua-yuan street, Chao-yang district, Beijing 100029, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)