单位:[1]Department of Anesthesiology, Beijing YouAn Hospital, Capital Medical University, Beijing, P.R. China[2]Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing, P.R. China临床科室麻醉科麻醉科首都医科大学附属北京友谊医院
Background: Ultrasound with developing line may by suitable for medical personnel who are inexperienced in the use of ultrasound-guided radial artery puncture. In this trial, we assessed whether this technology could increase the success rate of radial artery puncture performed by interns. Material/Methods: Seventy-seven patients undergoing general anesthesia were enrolled and randomly divided into 2 groups: an ultrasound with developing line group and a traditional ultrasound group. All radial artery punctures were performed by interns who received theoretical explanation (including video demonstration of puncture) and on-site guidance puncture once. The primary end-point was the success rate of cannulation at the first attempt and the secondary end-point was cannulation failure rate. Results: The success rate of cannulation at the first attempt in ultrasound in the developing line group was significantly higher than that in the traditional ultrasound group (proportion difference: 34.21%, 95% confidence interval [CI], -0.5483 to -0.1334; P=0.0025). However, no significant between-group difference was observed with respect to failure rate (mean difference 95% CI, (-0.0084 to 0.2743; P=0.0866). The ultrasonic location time in the ultrasound with developing line group was significantly lower than that in the traditional ultrasound group (mean difference -12.4 seconds, 95% CI, 10.64 to 13.98 s; P<0.0000). Conclusions: Use of ultrasound with developing line significantly improved the success rate of radial artery puncture per- formed by interns as compared to that with use of traditional dynamic ultrasound guidance technology.
基金:
Beijing Municipal Science and Technology CommissionBeijing Municipal Science & Technology Commission [Z171100001017036]
第一作者单位:[1]Department of Anesthesiology, Beijing YouAn Hospital, Capital Medical University, Beijing, P.R. China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
Quan Zhefeng,Chao Luo,Liang Zhang,et al.Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors: A Randomized Trial[J].MEDICAL SCIENCE MONITOR.2019,25:1566-1571.doi:10.12659/MSM.913044.
APA:
Quan Zhefeng,Chao Luo,Liang Zhang,Xin Li,He, Haili&Ping Chi.(2019).Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors: A Randomized Trial.MEDICAL SCIENCE MONITOR,25,
MLA:
Quan Zhefeng,et al."Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors: A Randomized Trial".MEDICAL SCIENCE MONITOR 25.(2019):1566-1571