Application of Optimized Ultrasonic Localization System for Radial Artery Puncture by Intern Doctors: A Randomized Trial

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Anesthesiology, Beijing YouAn Hospital, Capital Medical University, Beijing, P.R. China [2]Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing, P.R. China
出处:
ISSN:

关键词: Internship and Residency Radial Artery Ultrasonography

摘要:
Background: Ultrasound with developing line may by suitable for medical personnel who are inexperienced in the use of ultrasound-guided radial artery puncture. In this trial, we assessed whether this technology could increase the success rate of radial artery puncture performed by interns. Material/Methods: Seventy-seven patients undergoing general anesthesia were enrolled and randomly divided into 2 groups: an ultrasound with developing line group and a traditional ultrasound group. All radial artery punctures were performed by interns who received theoretical explanation (including video demonstration of puncture) and on-site guidance puncture once. The primary end-point was the success rate of cannulation at the first attempt and the secondary end-point was cannulation failure rate. Results: The success rate of cannulation at the first attempt in ultrasound in the developing line group was significantly higher than that in the traditional ultrasound group (proportion difference: 34.21%, 95% confidence interval [CI], -0.5483 to -0.1334; P=0.0025). However, no significant between-group difference was observed with respect to failure rate (mean difference 95% CI, (-0.0084 to 0.2743; P=0.0866). The ultrasonic location time in the ultrasound with developing line group was significantly lower than that in the traditional ultrasound group (mean difference -12.4 seconds, 95% CI, 10.64 to 13.98 s; P<0.0000). Conclusions: Use of ultrasound with developing line significantly improved the success rate of radial artery puncture per- formed by interns as compared to that with use of traditional dynamic ultrasound guidance technology.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2017]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2017版] 出版当年五年平均[2013-2017] 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Department of Anesthesiology, Beijing YouAn Hospital, Capital Medical University, Beijing, P.R. China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)