高级检索
当前位置: 首页 > 详情页

Predicting forced vital capacity (FVC) using support vector regression (SVR)

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Chinese Acad Sci, Inst Elect, Beijing, Peoples R China [2]Univ Chinese Acad Sci, Beijing, Peoples R China [3]China Japan Friendship Hosp, Beijing, Peoples R China
出处:
ISSN:

关键词: machine learning chronic obstructive pulmonary disease forced vital capacity prediction

摘要:
Objective: Spirometry, as the gold standard approach in the diagnosis of chronic obstructive pulmonary disease (COPD), has strict end of test (EOT) criteria (e.g. complete exhalation), which cannot be met by patients with compromised health states. Thus, significant parameters measured by spirometry, such as forced vital capacity (FVC), have limited accuracies. To address this issue, the present study aimed to develop models based on support vector regression (SVR) to predict values of FVC under the condition that the EOT criteria were not fully met. Approach: The prediction models for the quantification of FVC were developed based on SVR. A total of 354 subjects underwent conventional spirometry (CS), and the resulting data of forced expiratory volumes in 1 s (FEV1), peak expiratory flow (PEF), age and gender were used as input features, while the resulting values of the FVC were used as the target feature in the prediction models. Next, three prediction models (mixed model, normal model and abnormal model) were established according to the criterion in the diagnosis of COPD that a postbronchodilator shows an FEV1/FVC ratio lower than 0.70. Then, 35 subjects were recruited to be tested using both CS and a low-degree-of-EOT criteria spirometry (LDCS), which did not fully meet the EOT criteria of CS. In LDCS, subjects were allowed to terminate the procedure at their own will at any time after the technicians had assumed that both acceptable values of FEV1 and PEF had been obtained. Quantified values of FVC derived from both CS and LDCS were compared to validate the performances of the developed prediction models. Main results: The FVC prediction performances of the normal model and abnormal model were better than that of the mixed model. The root mean squared error are lower than 0.35 l and the accuracies are higher up to 95%. One-tailed t test results demonstrate that the absolute differences in the measured and predicted values are not significantly different from 0.15 l for both the abnormal model and the normal model. Significance: Our study shows the possibility of predicting FVC with acceptable precision in cases where the EOT criteria of spirometry were not fully met, which can be beneficial for patients who cannot or did not achieve full exhalation in spirometry.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 生物
小类 | 4 区 生物物理 4 区 工程:生物医学 4 区 生理学
最新[2025]版:
大类 | 4 区 医学
小类 | 3 区 生物物理 3 区 生理学 4 区 工程:生物医学
JCR分区:
出版当年[2017]版:
Q2 ENGINEERING, BIOMEDICAL Q3 PHYSIOLOGY Q3 BIOPHYSICS
最新[2023]版:
Q3 BIOPHYSICS Q3 ENGINEERING, BIOMEDICAL Q3 PHYSIOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2017版] 出版当年五年平均[2013-2017] 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者单位: [1]Chinese Acad Sci, Inst Elect, Beijing, Peoples R China [2]Univ Chinese Acad Sci, Beijing, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)