高级检索
当前位置: 首页 > 详情页

Injectable Shape-Memorizing Three-Dimensional Hyaluronic Acid Cryogels for Skin Sculpting and Soft Tissue Reconstruction

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Tissue Engineering and Wound Healing Laboratory, Division of Plastic Surgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA [2]Department of Plastic and Reconstructive Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China. [3]Department of Plastic Surgery, China-Japan Friendship Hospital, Beijing, China. [4]Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA [5]John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA [6]Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA
出处:
ISSN:

关键词: hyaluronic acid filler shape-memorizing injectable skin sculpturing soft tissue reconstruction scaffold regeneration plastic surgery

摘要:
Introduction: Hyaluronic acid (HA)-based fillers are used for various cosmetic procedures. However, due to filler migration and degradation, reinjections of the fillers are often required. Methacrylated HA (MA-HA) can be made into injectable shape-memorizing fillers (three-dimensional [3D] MA-HA) aimed to address these issues. In this study, shape retention, firmness, and biocompatibility of 3D MA-HA injected subcutaneously in mice were evaluated. Materials and Methods: Fifteen mice, each receiving two subcutaneous injections in their back, were divided into four groups receiving HA, MA-HA, 3D MA-HA, or saline, respectively. Digital imaging, scanning electron microscope (SEM) and in vivo imaging system (IVIS), durometry, and histology were utilized to evaluate in vitro/vivo degradation and migration, material firmness, and the angiogenic (CD31) and immunogenic (CD45) response of the host tissue toward the injected materials. Results: Digital imaging, SEM, and IVIS revealed that 3D MA-HA fillers maintained their predetermined shape for at least 30 days in vitro and in vivo. Little volume effects were noted in the saline and other control groups. There were no differences in skin firmness between the groups or over time. Histology showed intact skin architecture in all groups. Three-dimensional MA-HA maintained its macroporous structure with significant angiogenesis at the 3D MA-HA/skin interfaces and throughout the 3D MA-HA. There was no significant inflammatory response to any of the injected materials. Conclusion: 3D MA-HA showed remarkable tissue compatibility, compliance, and shape predictability, as well as retention, and thus might be suitable for various skin sculpting and soft tissue reconstruction purposes.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2016]版:
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 细胞生物学 3 区 工程:生物医学 4 区 细胞与组织工程 4 区 材料科学:生物材料
JCR分区:
出版当年[2015]版:
最新[2023]版:
Q2 ENGINEERING, BIOMEDICAL Q3 CELL & TISSUE ENGINEERING Q3 CELL BIOLOGY Q3 MATERIALS SCIENCE, BIOMATERIALS

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2015版] 出版当年五年平均[2011-2015] 出版前一年[2014版]

第一作者:
第一作者单位: [1]Tissue Engineering and Wound Healing Laboratory, Division of Plastic Surgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA [2]Department of Plastic and Reconstructive Surgery, Shanghai Ninth People’s Hospital, Shanghai Jiao Tong University, School of Medicine, Shanghai, China.
通讯作者:
通讯机构: [1]Tissue Engineering and Wound Healing Laboratory, Division of Plastic Surgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA [6]Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, MA, USA [*1]Department of Anesthesiology, Perioperative and Pain Medicine Department of Surgery, Tissue Engineering and Wound Healing Laboratory
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)