单位:[1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA[2]China Japan Friendship Hosp, Dept Radiol, Beijing, Peoples R China[3]GE Healthcare, Global Appl Sci Lab, San Diego, CA USA[4]Univ Calif San Diego, Dept Pathol, San Diego, CA 92103 USA[5]Univ Calif San Diego, Dept Neurosci, San Diego, CA 92103 USA[6]Fudan Univ, Huadong Hosp, Dept Radiol, Shanghai 200433, Peoples R China
White matter of the brain contains a majority of long T2 components as well as a minority of short T2 components. These are not detectable using clinical magnetic resonance imaging (MRI) sequences with conventional echo times (TEs). In this study we used ultrashort echo time (UTE) sequences to investigate the ultrashort 12 components in white matter of the brain and quantify their T2*s and relative proton densities (RPDs) (relative to water with a proton density of 100%) using a clinical whole body 31 scanner. An adiabatic inversion recovery prepared dual echo UTE (IR-dUTE) sequence was used for morphological imaging of the ultrashort T2 components in white matter. IR-dUTE acquisitions at a constant TR of 1000 ms and a series of TIs were performed to determine the optimal TI which corresponded to the minimum signal to noise ratio (SNR) in white matter of the brain on the second echo image. T2's -Orthe ultraiErre T2 corriPonents were ifuantified u-slhg exponential decay fitting of the IR-dUTE signal at a series of TEs. RPD was quantified by comparing IR-dUTE signal of the ultrashort T2 components with that of a rubber phantom. Nine healthy volunteers were studied. The IRdUTE sequence provided excellent image contrast for the ultrashort T2 components in white matter of the brain with a mean signal to noise ratio of 18.7 +/- 3.7 and a contrast to noise ratio of 14.6 +/- 2.4 between the ultrashort T2 white matter and gray matter in a 4.4 min scan time with a nominal voxel size of 1.25 x 125 x 5.0 mm(3). On average a T2* value of 0.42 +/- 0.08 ms and a RPD of 4.05 0.88% were demonstrated for the ultrashort T2 components in white matter of the brain of healthy volunteers at 31. (C) 2013 Elsevier Inc. All rights reserved.
基金:
GE HealthcareGeneral ElectricGE Healthcare [1R21 AR063894-01A1]; NATIONAL CENTER FOR RESEARCH RESOURCESUnited States Department of Health & Human ServicesNational Institutes of Health (NIH) - USANIH National Center for Research Resources (NCRR) [P20RR021938] Funding Source: NIH RePORTER; NATIONAL INSTITUTE OF ARTHRITIS AND MUSCULOSKELETAL AND SKIN DISEASESUnited States Department of Health & Human ServicesNational Institutes of Health (NIH) - USANIH National Institute of Arthritis & Musculoskeletal & Skin Diseases (NIAMS) [R21AR063894] Funding Source: NIH RePORTER
语种:
外文
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2013]版:
大类|2 区医学
小类|1 区神经成像1 区核医学2 区神经科学
最新[2025]版:
大类|2 区医学
小类|1 区神经成像2 区神经科学2 区核医学
JCR分区:
出版当年[2012]版:
Q1NEUROSCIENCESQ1NEUROIMAGINGQ1RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1NEUROIMAGINGQ1NEUROSCIENCESQ1RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者单位:[1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA[*1]Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
通讯作者:
通讯机构:[1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA[*1]Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
推荐引用方式(GB/T 7714):
Du Jiang,Ma Guolin,Li Shihong,et al.Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner[J].NEUROIMAGE.2014,87:32-41.doi:10.1016/j.neuroimage.2013.10.053.
APA:
Du, Jiang,Ma, Guolin,Li, Shihong,Carl, Michael,Szeverenyi, Nikolaus M....&Bydder, Graeme M..(2014).Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner.NEUROIMAGE,87,
MLA:
Du, Jiang,et al."Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner".NEUROIMAGE 87.(2014):32-41