高级检索
当前位置: 首页 > 详情页

Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA [2]China Japan Friendship Hosp, Dept Radiol, Beijing, Peoples R China [3]GE Healthcare, Global Appl Sci Lab, San Diego, CA USA [4]Univ Calif San Diego, Dept Pathol, San Diego, CA 92103 USA [5]Univ Calif San Diego, Dept Neurosci, San Diego, CA 92103 USA [6]Fudan Univ, Huadong Hosp, Dept Radiol, Shanghai 200433, Peoples R China
出处:
ISSN:

关键词: Ultrashort echo time Adiabatic IR Ultrashort T2 White matter T2* Proton density

摘要:
White matter of the brain contains a majority of long T2 components as well as a minority of short T2 components. These are not detectable using clinical magnetic resonance imaging (MRI) sequences with conventional echo times (TEs). In this study we used ultrashort echo time (UTE) sequences to investigate the ultrashort 12 components in white matter of the brain and quantify their T2*s and relative proton densities (RPDs) (relative to water with a proton density of 100%) using a clinical whole body 31 scanner. An adiabatic inversion recovery prepared dual echo UTE (IR-dUTE) sequence was used for morphological imaging of the ultrashort T2 components in white matter. IR-dUTE acquisitions at a constant TR of 1000 ms and a series of TIs were performed to determine the optimal TI which corresponded to the minimum signal to noise ratio (SNR) in white matter of the brain on the second echo image. T2's -Orthe ultraiErre T2 corriPonents were ifuantified u-slhg exponential decay fitting of the IR-dUTE signal at a series of TEs. RPD was quantified by comparing IR-dUTE signal of the ultrashort T2 components with that of a rubber phantom. Nine healthy volunteers were studied. The IRdUTE sequence provided excellent image contrast for the ultrashort T2 components in white matter of the brain with a mean signal to noise ratio of 18.7 +/- 3.7 and a contrast to noise ratio of 14.6 +/- 2.4 between the ultrashort T2 white matter and gray matter in a 4.4 min scan time with a nominal voxel size of 1.25 x 125 x 5.0 mm(3). On average a T2* value of 0.42 +/- 0.08 ms and a RPD of 4.05 0.88% were demonstrated for the ultrashort T2 components in white matter of the brain of healthy volunteers at 31. (C) 2013 Elsevier Inc. All rights reserved.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 2 区 医学
小类 | 1 区 神经成像 1 区 核医学 2 区 神经科学
最新[2025]版:
大类 | 2 区 医学
小类 | 1 区 神经成像 2 区 神经科学 2 区 核医学
JCR分区:
出版当年[2012]版:
Q1 NEUROSCIENCES Q1 NEUROIMAGING Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 NEUROIMAGING Q1 NEUROSCIENCES Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2012版] 出版当年五年平均[2008-2012] 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者单位: [1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA [*1]Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
通讯作者:
通讯机构: [1]Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA [*1]Univ Calif San Diego, Dept Radiol, 200 West Arbor Dr, San Diego, CA 92103 USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)