高级检索
当前位置: 首页 > 详情页

Ability of lower teardrop edge to restore anatomical hip center height in total hip arthroplasty

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

单位: [1]China Japan Friendship Hosp, Dept Bone & Joint Surg, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: total hip arthroplasty teardrop hip center height inclination anteversion

摘要:
Background The acetabular teardrop is often used to guide acetabular component placement in total hip arthroplasty (THA). Placing the lower acetabular component aspect at the same level as the lower teardrop edge was assumed to restore the hip center of rotation. Here we radiographically analyzed the relationship between cup center and normal contralateral acetabulum center height on unilateral THA using this placement method. Methods A total of 106 unilateral THA cases with normal contralateral acetabula were reviewed and the vertical and horizontal distances in relation to the lower acetabular teardrop edge from both hip joint centers, cup inclination, and anteversion were measured radiographically. The paired t-test was used to compare left and right hip center heights. Scatter plots and Pearson's correlation coefficients were used to evaluate differences in hip center heights, cup anteversion, inclination angles, and medialized cup center distance compared to the contralateral hip joint. Results Cup center height was significantly greater (P<0.01) than contralateral hip joint center height (93.4% in the 0-5 mm range, 6.6% >5 mm). There was a weak correlation between hip center height difference and inclination (r=0.376, P<0.01) and between difference and anteversion (r=0.310, P<0.01) but no correlation between difference and outer cup diameter (r=0.184, P=0.058) or difference and medialized cup center distance (r=-0.098, P=0.318). Conclusions Although this method did not exactly replicate anatomic hip center height, the clinical significance of cup center height and anatomic hip center height differences is negligible. This acetabular component placement method has high simplicity, reliability, and stability.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2013]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2012]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2012版] 出版当年五年平均[2008-2012] 出版前一年[2011版] 出版后一年[2013版]

第一作者:
第一作者单位: [1]China Japan Friendship Hosp, Dept Bone & Joint Surg, Beijing 100029, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)