高级检索
当前位置: 首页 > 详情页

Systematic Review of Randomized Controlled Trials of Different Types of Patch Materials during Carotid Endarterectomy

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]China Japan Friendship Hosp, Ctr Cardiovasc, Beijing, Peoples R China [2]China Japan Friendship Hosp, Clin Res Inst, Beijing, Peoples R China
出处:
ISSN:

摘要:
Background and Purpose: Carotid endarterectomy (CEA) with patch angioplasty produces greater results than with primary closure; however, there remains uncertainty on the optimal patch material in CEA. A systematic review of randomized controlled trials (RCTs) was performed to evaluate the effect of angioplasty using venous patch versus synthetic patch material, and Dacron patch versus polytetrafluoroethelene (PTFE) patch material during CEA. Methods: A multiple electronic health database screening was performed including the Cochrane library, Pubmed, Ovid, EMBASE and Google Scholar on all randomized controlled trials (RCTs) published before November 2012 that compared the outcomes of patients undergoing CEA with venous patch versus synthetic patch. RCTs were included if they compared carotid patch angioplasty with autologus venous patch versus synthetic patch material, or compared one type of synthetic patch with another. Results: Thirteen RCTs were identified. Ten trials, involving 1946 CEAs, compared venous patch with synthetic patch materials. Two trials, involving 400 CEAs in 380 patients, compared Dacron patch with PTFE patch. The hemostasis time in CEA with PTFE patch was significantly longer than with venous patch (P<0.0001), and longer than with Dacron patch (P<0.0001). There was no significant difference of mortality rate, stroke rate, restenosis, and operative time in CEA with venous patch versus synthetic patch material, or in CEA with Dacron patch versus PTFE patch (all P>0.05). One RCT of 95 CEAs in 92 patients compared bovine pericardium with Dacron patch, and demonstrated a statistically significant decrease in intraoperative suture line bleeding with bovine pericardium compared with Dacron patch (P<0.001). Conclusions: The hemostasis time in CEA with PTFE patch was longer than with venous patch or Dacron patch. The overall perioperative and long-term mortality rate, stroke rate, restenosis, and operative time were similar when using venous patch versus synthetic patch material or Dacron patch versus PTFE patch material during CEA. More data are required to clarify differences between different patch materials.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 2 区 生物
小类 | 2 区 生物学
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2011]版:
Q1 BIOLOGY
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2011版] 出版当年五年平均[2007-2011] 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]China Japan Friendship Hosp, Ctr Cardiovasc, Beijing, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)