高级检索
当前位置: 首页 > 详情页

Shielding effect of thyroid collar for digital panoramic radiography

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Peking Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Radiol, Beijing 100081, Peoples R China [2]China Japan Friendship Hosp, Stomatol Ctr, Beijing, Peoples R China
出处:
ISSN:

关键词: panoramic radiography digital panoramic radiography radiation dosimetry effective dose thyroid gland

摘要:
Objectives: To evaluate the shielding effect of thyroid collar for digital panoramic radiography. Methods: 4 machines [Orthopantomograph (R) OP200 (Instrumentarium Dental, Tuusula, Finland), Orthophos CD (Sirona Dental Systems GmbH, Bensheim, Germany), Orthophos XG Plus (Sirona Dental Systems GmbH) and ProMax (R) (Planmeca Oy, Helsinki, Finland)] were used in this study. Average tissue-absorbed doses were measured using thermoluminescent dosemeter chips in an anthropomorphic phantom. Effective organ and total effective doses were derived according to the International Commission of Radiological Protection 2007 recommendations. The shielding effect of one collar in front and two collars both in front and at the back of the neck was measured. Results: The effective organ doses of the thyroid gland obtained from the 4 panoramic machines were 1.12 mu Sv for OP200, 2.71 mu Sv for Orthophos CD, 2.18 mu Sv for Orthophos XG plus and 2.20 mu Sv for ProMax, When no thyroid collar was used. When 1 collar was used in front of the neck, the effective organ doses of the thyroid gland were 1.01 mu Sv (9.8% reduction), 2.45 mu Sv (9.6% reduction), 1.76 mu Sv (19.3% reduction) and 1.70 mu Sv (22.7% reduction), respectively. Significant differences in dose reduction were found for Orthophos XG Plus and ProMax. When two collars were used, the effective organ doses of the thyroid gland were also significantly reduced for the two machines Orthophos XG Plus and ProMax. The same trend was observed in the total effective doses for the four machines. Conclusions: Wearing a thyroid collar was helpful when the direct digital panoramic imaging systems were in use, whereas for the indirect digital panoramic imaging systems, the thyroid collar did not have an extra protective effect on the thyroid gland and whole body.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 3 区 牙科与口腔外科 4 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 牙科与口腔外科 3 区 核医学
JCR分区:
出版当年[2011]版:
Q3 DENTISTRY, ORAL SURGERY & MEDICINE Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 DENTISTRY, ORAL SURGERY & MEDICINE Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2011版] 出版当年五年平均[2007-2011] 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]Peking Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Radiol, Beijing 100081, Peoples R China [2]China Japan Friendship Hosp, Stomatol Ctr, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Peking Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Radiol, Beijing 100081, Peoples R China [*1]Peking Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Radiol, 22 Zhongguancun Nandajie, Beijing 100081, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题