In vivo proton MRS of normal pancreas metabolites during breath-holding and free-breathing

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China [2]GE Co, GE China Co Ltd, Healthcare, Beijing, Peoples R China
出处:
ISSN:

摘要:
AIM: To characterize normal pancreas metabolites using in vivo proton magnetic resonance spectroscopy (H-1 MRS) at 3 T under conditions of breath-holding and free-breathing. MATERIALS AND METHODS: The pancreases of 32 healthy volunteers were examined using H-1 MRS during breath-holding and free-breathing acquisitions in a single-voxel point-resolved selective spectroscopy sequence (PRESS) technique using a 3 T MRI system. Resonances were compared between paired spectra of the two breathing modes. Furthermore, correlations between lipid (Lip) content and age, body-mass index (BMI), as well as choline (Cho) peak visibility of the normal pancreas were analysed during breath-holding. RESULTS: Twenty-nine pairs of spectra were successfully obtained showing three major resonances, Lip, Cho, cholesterol and the unsaturated parts of the olefinic region of fatty acids (Chol + Unsat). Breath-hold spectra were generally better, with higher signal-to-noise ratios (SNR; Z=-2.646, p = 0.008) and Cho peak visible status (Z=-2.449, p = 0.014). Correlations were significant between spectra acquired by the two breathing modes, especially for Lip height, Lip area, and the area of other peaks at 1.9-4.1 ppm. However, the Lip resonance was significantly different between the spectra of the two breathing modes (p < 0.05). In the breath-holding spectra, there were significant positive correlations between Lip peak height, area, and age (r = 0.491 and 0.521, p = 0.007 and 0.004), but not between Lip peak area and BMI. There was no statistical difference in Cho resonances between males and females. The Lip peak height and area were significantly higher in the Cho peak invisible group than in the Cho peak visible group (t = 2.661 and 2.353, p = 0.030 and 0.043). CONCLUSION: In vivo H-1 MRS of the normal pancreas at 3 T is technically feasible and can characterize several metabolites. H-1 MRS during breath-holding acquisition is superior to that during free-breathing acquisition. (C) 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2011]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2010]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2010版] 出版当年五年平均[2006-2010] 出版前一年[2009版] 出版后一年[2011版]

第一作者:
第一作者单位: [1]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing 100050, Peoples R China [*1]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, 95 Yong An Rd, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题