A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results
Background Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently, investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease. Methods A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group: 156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length 40 mm, reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years, including major adverse cardiac events (cardiac death, myocardial infarction, or target-lesion revascularization) and stent thrombosis. Results Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25 +/- 0.33) mm vs. (0.57 +/- 0.55) mm, diff (95% Cl) -0.23 (-0.32, -0.14), P<0.0001; in-segment (0.25 0.33) mm vs. (0.42 +/- 0.55) mm, diff (95% Cl) -0.13 (-0.23, -0.02), P=0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P=0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P=0.0495) at 2 years. The two-year major adverse cardiac events (MACE) rate was lower for the TIVOLI group, but not significantly different (6.6% vs. 10.9%, P=0.1630). Conclusions TIVOLI was superior to ENDEAVOR stent with respect to late lumen loss at 8 months, and it yielded both lower rates of angiographic binary restenosis at 8 months and target lesion revascularization (TLR) at 2 years. The MACE rate at 2 years was comparable in both groups. Chin Med J2011;124(6):811-816
第一作者单位:[2]Chinese Acad Med Sci, Cardiac Catheterizat Lab, Cardiovasc Inst, Beijing 100037, Peoples R China[3]Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China[4]Peking Union Med Coll, Beijing 100037, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
Xu Bo,Dou Ke-fei,Han Ya-ling,et al.A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results[J].CHINESE MEDICAL JOURNAL.2011,124(6):811-816.doi:10.3760/cma.j.issn.0366-6999.2011.06.003.
APA:
Xu Bo,Dou Ke-fei,Han Ya-ling,Lue Shu-zheng,Yang Yue-jin...&Gao Run-lin.(2011).A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results.CHINESE MEDICAL JOURNAL,124,(6)
MLA:
Xu Bo,et al."A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results".CHINESE MEDICAL JOURNAL 124..6(2011):811-816