CT colonography and computer-aided detection: Effect of false-positive results on reader specificity and reading efficiency in a low-prevalence screening population

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 自然指数

单位: [1]Univ Coll Hosp, London NW1 2BU, England [2]St Marks Hosp, Dept Intestinal Imaging, Harrow, Middx, England [3]Beijing Friendship Hosp, Dept Radiol, Beijing, Peoples R China [4]Univ Wisconsin, Sch Med, Abdominal Imaging Sect, Madison, WI 53706 USA
出处:
ISSN:

摘要:
Purpose: To retrospectively evaluate the effect of increasing numbers of computer-aided detection (CAD)-generated false-positive (FP) marks on reader specificity and reporting times by using computed tomographic (CT) colonography in a low-prevalence screening population. Materials and Methods: Ethics committee approval and informed consent were obtained for this HIPAA-compliant study. Four readers each read 48 data sets (26 men, 22 women; mean age, 57 years) from a screening population (three containing polyps) without CAD application, followed by review of the CAD output and recorded findings and diagnostic confidence. The 45 data sets that were designated as normal were chosen such that 22 generated 15 or fewer FP CAD marks and 23 generated more than 15 FP CAD marks. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated with and without CAD. The relationships between the number of CAD FP marks and reader confidence, reporting times, and correct data set classification were analyzed by using linear and logistic regression. Results: Across all readers, CAD resulted in four additional FP detections. Overall reader sensitivity and specificity (6-mm polyp threshold) before and after CAD application were 0.75 (95% confidence interval [CI]: 0.43, 0.95) versus 0.83 (95% CI: 0.52, 0.98) and 0.96 (95% CI: 0.91, 0.98) versus 0.93 (95% CI: 0.88, 0.96), respectively. The area under the ROC curve increased from 0.57 (95% CI: 0.34, 0.80) to 0.61 (95% CI: 0.42, 0.80). There was no correlation between an increasing number of CAD FP marks and reader confidence (P = .71) or correct study classification (P = .23), but there was a positive correlation with CAD-assisted reading times (0.06 [95% CI: 0.02, 0.10], P = .002). Conclusion: Increasing numbers of CAD FP marks did not adversely influence correct reader study classification or diagnostic confidence, although reporting times did increase. (c) RSNA, 2008.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2007]版:
大类 | 2 区 医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2006]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均[2021-2025] 出版当年[2006版] 出版当年五年平均[2002-2006] 出版前一年[2005版] 出版后一年[2007版]

第一作者:
第一作者单位: [1]Univ Coll Hosp, London NW1 2BU, England [*1]Univ Coll Hosp, 2F Podium,235 Euston Rd, London NW1 2BU, England
通讯作者:
通讯机构: [1]Univ Coll Hosp, London NW1 2BU, England [*1]Univ Coll Hosp, 2F Podium,235 Euston Rd, London NW1 2BU, England
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:819 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)