高级检索
当前位置: 首页 > 详情页

Biomechanical and morphometric properties of the arterial wall referenced to the zero-stress state in experimental diabetes

| 认领 | 导出 |

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Aarhus Univ, Inst Expt Clin Res, DK-8000 Aarhus, Denmark [2]China Japan Friendship Hosp, Inst Clin Med Sci, Beijing, Peoples R China [3]Univ Aalborg, MIBA, Ctr Sensory Motor Interact, Aalborg, Denmark [4]Aalborg Hosp, Dept A, Aalborg, Denmark [*1]Skejby Univ Hosp, Inst Expt Clin Res, Biomech Lab, DK-8200 Aarhus N, Denmark
出处:
ISSN:

关键词: diabetic angiopathy morphometry stress-strain arterial stiffness zero-stress state

摘要:
Morphometric and passive biomechanical properties were studied in isolated segments of the thoracic and abdominal aorta, left common carotid artery, left femoral artery and the left pulmonary artery in 20 non-diabetic and 28 streptozotocin (STZ)-induced diabetic rats. The diabetic and non-diabetic rats were divided into groups living 1, 4, 8, and 12 weeks after the induction of diabetes (n=7 for each diabetic group) or sham injection (n=5 for each group). The mechanical test was performed as a distension experiment where the proximal end of the arterial segment was connected via a tube to the container used for applying pressures to the segment and the distal end was left free. The vessel diameter and length were obtained from digitized images of the arterial segments at pre-selected pressures and at no-load and zero-stress states. Circumferential and longitudinal stresses (force per area) and strains (deformation) were computed from the length, diameter and pressure data and from the zero-stress state data. The zero-stress state was obtained by cutting vessel rings radially causing the rings to open up into a sector. Diabetes was associated with pronounced morphometric changes, e.g., wall thickness. With respect to the biomechanical data, the opening angle increased and reached a plateau in 4 weeks after which it decreased again (p <0.05). The opening angle was smallest in the thoracic aorta and largest in the pulmonary artery. Furthermore, it was found that the circumferential stiffness of the arteries studied increased with the duration of diabetes. In the longitudinal direction significant differences were found 8 weeks after injection of STZ in all arteries except the pulmonary artery. In the 12 weeks group, the femoral artery was stiffest in the circumferential direction whereas the thoracic aorta was stiffest in the longitudinal direction. The accumulated serum glucose level correlated with the arterial wall thickness and elastic modulus (correlation coefficient between 0.56 and 0.81).

语种:
被引次数:
WOS:
JCR分区:
出版当年[1998]版:
Q2 ENGINEERING, BIOMEDICAL Q3 HEMATOLOGY Q3 BIOPHYSICS
最新[2023]版:
Q4 BIOPHYSICS Q4 ENGINEERING, BIOMEDICAL Q4 HEMATOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[1998版] 出版当年五年平均[1994-1998] 出版前一年[1997版] 出版后一年[1999版]

第一作者:
通讯作者:
通讯机构: [*1]Skejby Univ Hosp, Inst Expt Clin Res, Biomech Lab, DK-8200 Aarhus N, Denmark
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)