Computational fluid dynamics study of the effect of transverse sinus stenosis on the blood flow pattern in the ipsilateral superior curve of the sigmoid sinus
单位:[1]Department of Interventional Radiography, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China医技科室影像中心放射介入科首都医科大学附属北京友谊医院[2]College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China
Objective To investigate the effect of different types of transverse sinus stenosis on blood flow patterns in the ipsilateral superior curve of the sigmoid sinus. Methods According to the morphology of transverse and sigmoid sinus sections in pulsatile tinnitus patients, ten idealized models with different degrees and positions of transverse sinus stenosis were constructed. Computational fluid dynamics simulations were performed to compare the hemodynamic characteristics among these models. Follow-up images of previous cases were included, which preliminarily confirmed the hypothesis that bone plate erosion of the sigmoid sinus sulcus is related to blood flow impingement. Results Blood flow impingement on the superior curve of the sigmoid sinus wall intensified with increasing degree of stenosis and decreased with increasing distance between the stenosis and the sigmoid sinus. The impact zone was generally confined to the anterior and lateral walls of the superior curve of the sigmoid sinus. When the stenosis was located far from the middle of the transverse sinus, the blood flow impingement on the sigmoid sinus wall was very weak. Conclusions When stenosis is located far from the sigmoid sinus, the causes of tinnitus should be comprehensively considered instead of assuming that stenosis is the main cause. Bone plate erosion of the sigmoid sinus sulcus was promoted by blood flow impingement.
基金:
Research Foundation of Beijing Friendship Hospital, Capital Medical University [yyqdkt2019-26]
第一作者单位:[1]Department of Interventional Radiography, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
通讯作者:
推荐引用方式(GB/T 7714):
Han Yanjing,Xia Jun,Jin Long,et al.Computational fluid dynamics study of the effect of transverse sinus stenosis on the blood flow pattern in the ipsilateral superior curve of the sigmoid sinus[J].EUROPEAN RADIOLOGY.2021,31(8):6286-6294.doi:10.1007/s00330-020-07630-x.
APA:
Han Yanjing,Xia Jun,Jin Long,Qiao Aike,Su Tianhao...&Zhang Zhiyuan.(2021).Computational fluid dynamics study of the effect of transverse sinus stenosis on the blood flow pattern in the ipsilateral superior curve of the sigmoid sinus.EUROPEAN RADIOLOGY,31,(8)
MLA:
Han Yanjing,et al."Computational fluid dynamics study of the effect of transverse sinus stenosis on the blood flow pattern in the ipsilateral superior curve of the sigmoid sinus".EUROPEAN RADIOLOGY 31..8(2021):6286-6294