Validation of a novel UPLC-HRMS method for human whole-blood cyclosporine and comparison with a CMIA immunoassay

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 预警期刊

单位: [1]Department of Pharmacy, China-Japan Friendship Hospital, Beijing 100029, P.R. China
出处:
ISSN:

关键词: cyclosporine high-resolution mass spectrometry chemiluminescent microparticle immunoassay method comparison

摘要:
Therapeutic drug monitoring is an essential tool when managing the therapeutic use of immunosuppressant cyclosporine A (CsA) in cases with solid organ transplantation. In China, the concentration of CsA is primarily measured using immunoassays. However, existing literature recommends mass spectrometry as the current gold standard for the quantitation of CsA. In the present study, it was attempted to develop a novel application to determine CsA concentrations by using ultra-performance liquid chromatography coupled to high-resolution mass spectrometry (UPLC-HRMS). This technique was then compared with a commercially available chemiluminescent microparticle immunoassay (CMIA) and it was investigated how clinical factors may contribute to quantitation differences between the two methods. An UPLC-Orbitrap-MS method was developed to determine CsA concentrations and this method was validated using guidelines put forward by the Food and Drug Administration from the US. In total, 127 blood samples were acquired from patients undergoing kidney transplantation and analyzed by UPLC-HRMS and CMIA assays. The novel method provided sensitive, accurate and precise results. The mean CsA concentration measured by CMIA was significantly higher than that measured by UPLC-HRMS (85.70 +/- 48.99 vs. 67.06 +/- 34.56 ng/ml, P<0.0001). Passing Bablok analysis yielded a slope of 1.34 (95% CI: 1.22-1.47) and an intercept of -2.54 (95% CI: -10.29-5.52). A group of samples with a higher metabolic ratio (hydroxylated CsA/CsA>1) exhibited larger discrepancies, while a group of samples taken from patients with a longer post-transplantation time (>10 years) featured narrow 95% CIs from -15.32 to 65.69%, as determined by Bland-Altman analysis. In summary, a reliable, accurate and rapid UPLC-HRMS method for CsA analysis was successfully developed. The measurement of CsA by the CMIA assay in renal transplant patients should be further evaluated with a specific focus on positive bias.

基金:
语种:
WOS:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2019]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Pharmacy, China-Japan Friendship Hospital, Beijing 100029, P.R. China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Pharmacy, China-Japan Friendship Hospital, Beijing 100029, P.R. China [*1]Department of Pharmacy, China-Japan Friendship Hospital, 2 Yinghuadongjie Street, Chaoyang, Beijing 100029, P.R. China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)