A novel "three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty" for osteoporotic vertebral compression fracture: a prospective, controlled study
单位:[1]Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Xicheng District, Beijing, People’s Republic of China临床科室骨科骨科首都医科大学附属北京友谊医院
Background: Conventional percutaneous vertebroplasty (PVP) are mainly guided by C-arm fluoroscopy, and it usually leads to excessive X-ray radiation exposure to patients, surgeons, and anesthetists. Moreover, multi-time fluoroscope may prolong the operation time. 3D-printed template could help minimize fluoroscopy shot times and fluoroscopy dosage during operation, and shorten operation time. We perform this study to compare the efficacy and accuracy of PVP assisted by "three-dimensional printed individual guide template" versus conventional PVP. Method: Patients who suffered acute painful single segment osteoporotic vertebral compression fracture(OVCF) needed operative treatment were randomly assigned into three-dimensional printing individual guide template-assisted percutaneous vertebroplasty group (group A) or conventional PVP guided by C-arm fluoroscopy group (group B) at a 1:1 ratio. Fluoroscopy times for puncture points (FTPP), total radiation dosages (TRD), total fluoroscopy time (TFT), and total operation time (TOT) were recorded as the main evaluation factors to evaluate the two operation procedures. Results: A total of 36 acute painful single segment OVCF patients were successfully operated on, and each group has 18 patients. None of the patients presented symptomatic complications. The surgical success rate in group A was 94.4%(17/18), one patient in the group A was failed and then operated by conventional procedure. FTPP (1.8 0.8 in group A vs 5.2 1.9 in group B, P < 0.05), TRD (4.9 +/- 0.9 mGy vs 7.9 +/- 1.6 mGy, P < 0.05), TFT (16.7 +/- 2.9 vs 26.6 +/- 5.3, P < 0.05), and total operation time (19.4 +/- 2.4 min vs 27.8 +/- 4.0 min, P < 0.05) were presented statistically difference in the two groups. The incidence of cement leakage occurred in group A (3/18, 16.7%) was less than that occurred in group B (7/18, 38.9%) (P > 0.05). Conclusions: Compared with the conventional PVP, "three-dimensional-printed individual guide template-assisted PVP" could minimize fluoroscopy shot times during operation and fluoroscopy dosage, shorten operation time, and is a more precise and feasible operation method. Trial registration: The present study was registered with the Chinese Clinical Trial Registry (ChiCTR) (http://www.chictr.org.cn), and its registration no. is ChiCTR1900024283.
基金:
Beijing Municipal Science & Technology Commission, ChinaBeijing Municipal Science & Technology Commission [Z181100001718078]
第一作者单位:[1]Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Xicheng District, Beijing, People’s Republic of China
通讯作者:
推荐引用方式(GB/T 7714):
Pei Lun Hu,Ji Sheng Lin,Hai Meng,et al.A novel "three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty" for osteoporotic vertebral compression fracture: a prospective, controlled study[J].JOURNAL of ORTHOPAEDIC SURGERY and RESEARCH.2021,16(1):doi:10.1186/s13018-021-02471-w.
APA:
Pei Lun Hu,Ji Sheng Lin,Hai Meng,Nan Su,Yong Yang&Qi Fei.(2021).A novel "three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty" for osteoporotic vertebral compression fracture: a prospective, controlled study.JOURNAL of ORTHOPAEDIC SURGERY and RESEARCH,16,(1)
MLA:
Pei Lun Hu,et al."A novel "three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty" for osteoporotic vertebral compression fracture: a prospective, controlled study".JOURNAL of ORTHOPAEDIC SURGERY and RESEARCH 16..1(2021)