高级检索
当前位置: 首页 > 详情页

Effects of colloid preload on the incidence of hypotension in spinal anesthesia for cesarean section: a systematic review and meta-analysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 卓越:领军期刊 ◇ 中华系列

单位: [1]Department of Anesthesia, China-Japan Friendship Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China [2]Department of Anesthesia, China-Japan Friendship Hospital, Beijing, China.
出处:
ISSN:

关键词: Colloid Preload Spinal anesthesia Cesarean section

摘要:
Background: Hypotension is a common complication caused by spinal anesthesia (SA), which may have adverse impacts on the condition of the parturient and fetus. Liquid infusion was found to be relatively effective for reducing the incidence of hypotension. However, the question of whether colloid preload can optimize hemodynamic variables in the cesarean section remains controversial. This study aims to determine the effects of colloid preload on the incidence of hypotension induced by SA in elective cesarean section. Methods: Related keywords were searched on PubMed, EMBASE, and Cochrane Library from inception dates to May 2020. Studies included were evaluated for eligibility and quality. The primary outcome was the intra-operative incidence of hypotension and severe hypotension. The secondary outcomes included the lowest intra-operative systolic blood pressure, the maximal intra-operative heart rate, the intra-operative needs of ephedrine and phenylephrine, the incidence of maternal nausea and/or vomiting, and neonatal outcomes (umbilical artery pH and Apgar scores). Apart from the above, RevMan 5.3 was used for the data analysis. Results: Altogether nine randomized controlled trials were included in the meta-analysis. There were no significant differences in the incidence of intra-operative hypotension, severe hypotension, or neonatal outcomes between the colloid preload group and control group, except for the umbilical artery pH. Conclusion: This meta-analysis suggests that colloid preload does not significantly reduce the incidence of hypotension associated with SA in elective cesarean section.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2019]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Anesthesia, China-Japan Friendship Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, China
通讯作者:
通讯机构: [2]Department of Anesthesia, China-Japan Friendship Hospital, Beijing, China. [*1]Department of Anesthesia, China-Japan Friendship Hospital, Beijing 100029, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)