高级检索
当前位置: 首页 > 详情页

CT-guided preoperative localization of ground glass nodule: comparison between the application of embolization microcoil and the locating needle designed for pulmonary nodules

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, China-Japan Friendship Hospital, Beijing, China [2]Department of oncology comprehensive treatment, The Second Hospital of Chifeng, Inner Mongolia, China
出处:
ISSN:

摘要:
Objectives: To compare the efficacy and safety of preoperative localization of ground glass nodule (GGN) using embolization microcoils and the locating needles designed for pulmonary nodules. Methods: From June 2019 to December 2020, 429 patients who received CT-guided localization of single GGN before video-assisted thoracoscopic surgery (VATS) were enrolled. The diameter and depth of GGNs were 0.84 +/- 0.39cm and 1.66 +/- 1.37cm. Among 429 cases, the first 221 GGNs were marked with microcoils (the microcoil group), and the remaining 208 GGNs were marked with the locating needles designed for pulmonary nodules (the locating needle group). SPSS 17.0 statistical software was used to compare the marking success rate, marking time, marking-related complications between two groups. p values < 0.05 were considered statistically significant. Results: The marking time in the microcoil group was longer than that in the locating needle group (11.1 +/- 3.9 vs 8.2 +/- 2.0min, t = -7.87, p = 0.000). The marking success rate in the microcoil group was lower than that in the locating needle group (91.4% vs 98.6%, chi(2) = 11.27, p = 0.001). In the microcoil group, marking failures included 16 cases of microcoil dislocation and 3 cases of unsatisfactory microcoil position, while all 3 cases of marking failure in the locating needle group were due to unsatisfactory anchor position. No significant differences in the incidence of total complications (23.1% vs 22.1%), pneumothorax (18.1% vs 19.2%), hemorrhage (9.5% vs 9.1%), and hemoptysis (1.8% vs 1.4%) were observed between the two groups. All the complications were minor and did not need special treatment. Except for one case in the microcoil group, which was converted to thoracotomy, the remaining 428 GGNs were successfully resected by VATS. Conclusions: It is safe and effective to perform preoperative localization of GGN using either embolization microcoil or the locating needle designed for pulmonary nodules. The locating needle is superior to microcoil for marking GGN in terms of procedure time and the success rate. The complication rate of both methods is similar. Advances in knowledge: The locating needle designed for pulmonary nodules has recently been used to mark pulmonary nodule. Its structure can effectively avoid dislocation after localization, and the marking process is simple and quick. Compared with localization using microcoil, it takes less time and has higher success rate to mark GGNs using the locating needle. The complication rate of both methods is similar.

语种:
WOS:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2019]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Radiology, China-Japan Friendship Hospital, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题