单位:[1]Peking Union Med Coll Hosp, Dept Vasc Surg, Beijing, Peoples R China[2]Peking Union Med Coll Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China[3]Tsinghua Univ, Sch Med, Beijing, Peoples R China[4]Peking Univ Canc Hosp & Inst, Dept Radiat Oncol, Key Lab Carcinogenesis & Translat Res, Minist Educ Beijing, Beijing, Peoples R China[5]China Japan Friendship Hosp, Dept Ultrasound, Beijing, Peoples R China[6]Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Beijing, Peoples R China
Objective: The objectives of this study were to prospectively 1) explore the characteristics and enhanced patterns of carotid body tumors (CBTs) at color Doppler ultrasound (CDU) and contrast-enhanced ultrasonography (CEUS) qualitatively and quantitatively and 2) compare CDU and CEUS for their morphology and vascularity signature. Methods: CDU and CEUS with Sonovue (R) were used to evaluate 25 CBT lesions. The comparison between these ultrasonic modalities included the size, Shamblin type, vascularity, and feeding vessels of the lesion areas. The time-intensity curve (TIC) analysis was used to obtain the dynamics of the contrast-enhancement features of CBTs. Results: The TIC analysis presented a fast wash-in [wash-in time: 3.00 +/- 1.10 s, mean +/- SD] and slow wash-out [wash-out time: 58.79 +/- 24.21 s, mean +/- SD] pattern in the CBT lesions, with a high area under the curve (AUC) of 669.68 +/- 143.46 mm(2) (mean +/- SD). In comparison with CDU, CEUS was superior in identifying Shamblin type I or III CBT lesions (chi(2) = 17.389, p=0.002). It detected a significant difference in the AUC between moderate and marked vascularity groups (563.33 +/- 102.63 vs. 707.22 +/- 138.81, t=-2.311, p=0.031.), while CDU observed no significant difference between these two groups. Although CDU was more sensitive than CEUS in detecting feeding vessels (100% vs. 88%), CEUS better visualized the origins of feeding vessels (chi(2) = 9.162, p=0.010). Conclusion: CEUS can better investigate the Shamblin type and vascularity of CBT lesions than CDU. CBTs displayed a fast wash-in, slow wash-out pattern with high AUC in the TIC analysis in the CEUS mode. CDU is more sensitive in detecting feeding vessels than CEUS, while CEUS can better visualize the origins of feeding vessels.
第一作者单位:[1]Peking Union Med Coll Hosp, Dept Vasc Surg, Beijing, Peoples R China
共同第一作者:
通讯作者:
通讯机构:[1]Peking Union Med Coll Hosp, Dept Vasc Surg, Beijing, Peoples R China[2]Peking Union Med Coll Hosp, Dept Diagnost Ultrasound, Beijing, Peoples R China[5]China Japan Friendship Hosp, Dept Ultrasound, Beijing, Peoples R China[6]Chinese Acad Med Sci & Peking Union Med Coll, Peking Union Med Coll Hosp, State Key Lab Complex Severe & Rare Dis, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
Gu Guangchao,Zhang Xiaoyan,Shen Junyue,et al.Comparison of Contrast-Enhanced Ultrasonography to Color Doppler Ultrasound in Evaluation of Carotid Body Tumors[J].FRONTIERS in ONCOLOGY.2022,12:doi:10.3389/fonc.2022.872890.
APA:
Gu, Guangchao,Zhang, Xiaoyan,Shen, Junyue,Gulidanna, Shayan,Gao, Qiong...&Zheng, Yuehong.(2022).Comparison of Contrast-Enhanced Ultrasonography to Color Doppler Ultrasound in Evaluation of Carotid Body Tumors.FRONTIERS in ONCOLOGY,12,
MLA:
Gu, Guangchao,et al."Comparison of Contrast-Enhanced Ultrasonography to Color Doppler Ultrasound in Evaluation of Carotid Body Tumors".FRONTIERS in ONCOLOGY 12.(2022)