高级检索
当前位置: 首页 > 详情页

The Comparative Analysis of Antegrade Versus Retrograde Approach for a Failed Porous Tantalum Rod Removal During Conversion to Total Hip Arthroplasty

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Orthopedic Department, The First Affiliated Hospital, Zhejiang University, Hangzhou, Zhejiang, P.R. China [2]Orthopedic Department, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, P.R. China [3]Orthopedic Department, Xuzhou Cancer Hospital, Xuzhou, Jiangsu, P.R. China [4]Orthopedic Department, China Japan Friendship Hospital, Beijing, P.R. China
出处:
ISSN:

关键词: Arthroplasty Replacement Hip Tantalum

摘要:
Background: The failure of porous tantalum rods applied to patients with osteonecrosis of the femoral head (ONFH) has been increasingly reported during the last few years. Very few studies have reported methods for implant removal. This study aimed at comparing 2 procedures used for the removal of a failed tantalum rod during conversion to total hip arthroplasty (THA). Material/Methods: A total of 65 patients (65 hips), who underwent THA after failed implantation of a tantalum rod between June 2007 and December 2016, were retrospectively evaluated. These patients were classified into 2 groups depending on whether the antegrade approach (removal of the tantalum rod from the tip to the butt at the lateral femoral cortex, n=27) or retrograde approach (removal of the tantalum rod from the butt at the lateral femoral cortex to the proximal tip, n=38) was used for rod extraction. These 2 groups were compared for incision length, operation time, blood loss, fracture, tantalum debris, Harris hip scores, and the presence of osteolysis and/or radiolucency. Results: These 2 groups did not present any significant differences in terms of Harris hip score and incision length. However, the operation time (P=0.000), blood loss (P=0.000), amount of tantalum debris (P=0.000), and presence of radiolucency (P=0.046) were greater for the retrograde approach than for the antegrade approach. Conclusions: The risk of conversion to THA following failed tantalum rod implantation is high. In such cases, the antegrade procedure was found to be a simple and efficient method for removing the trabecular metal rod with the use of a trephine.

语种:
WOS:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
JCR分区:
出版当年[2018]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2018版] 出版当年五年平均[2014-2018] 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Orthopedic Department, The First Affiliated Hospital, Zhejiang University, Hangzhou, Zhejiang, P.R. China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)