18F-FDG PET for diagnosing painful arthroplasty/prosthetic joint infection

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Medical Healthcare Center, Beijing Friendship Hospital of Capital Medical University, Beijing 100050, China [2]Nuclear Medicine Department, Beijing Friendship Hospital of Capital Medical University, 95 YongAn Road, Xicheng District, Beijing 100050, China
出处:
ISSN:

关键词: Prosthetic infection Arthroplasty PET PET/CT

摘要:
Up to now, there were some studies about the role of 18F-FDG PET or PET/CT in the diagnosis of prosthetic joint infection after arthroplasty with different values of sensitivity and specificity. The purpose of this study was to systematically review the published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published regarding PET or PET/CT in patients suspicious of prosthetic infection was performed. Pooled sensitivity, specificity and area under the receiver operating characteristic (ROC) curve of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. Sixteen studies comprising 1101 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 87% [95% confidence interval (CI) 83-90%] on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 87% (95% CI 85-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.94 on a per prosthesis-based analysis. 18F-FDG PET or PET/CT demonstrated high sensitivity and specificity in subjects suspicious of prosthetic infection. However, various degrees of uptake in the asymptomatic patients are very common. Physicians should recognize these characteristics, and then 18F-FDG PET or PET/CT can act as an effective method in the diagnosis of prosthetic infection.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2016]版:
最新[2025]版
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2015]版:
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2015版] 出版当年五年平均[2011-2015] 出版前一年[2014版]

第一作者:
第一作者单位: [1]Medical Healthcare Center, Beijing Friendship Hospital of Capital Medical University, Beijing 100050, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)