高级检索
当前位置: 首页 > 详情页

Hepatic function imaging using dynamic Gd-EOB-DTPA enhanced MRI and pharmacokinetic modeling

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China. [2]Department of Hepatobiliary Surgery, China-Japan Friendship Hospital, Beijing, China. [3]Department of Radiology, China-Japan Friendship Hospital, Beijing, China. [4]Department of Radiology, University of Washington, Seattle, Washington, USA.
出处:
ISSN:

关键词: different output assumptions pharmacokinetic modeling Gd-EOB-DTPA function evaluation

摘要:
PurposeTo determine whether pharmacokinetic modeling parameters with different output assumptions of dynamic contrast-enhanced MRI (DCE-MRI) using Gd-EOB-DTPA correlate with serum-based liver function tests, and compare the goodness of fit of the different output assumptions. MethodsA 6-min DCE-MRI protocol was performed in 38 patients. Four dual-input two-compartment models with different output assumptions and a published one-compartment model were used to calculate hepatic function parameters. The Akaike information criterion fitting error was used to evaluate the goodness of fit. Imaging-based hepatic function parameters were compared with blood chemistry using correlation with multiple comparison correction. ResultsThe dual-input two-compartment model assuming venous flow equals arterial flow plus portal venous flow and no bile duct output better described the liver tissue enhancement with low fitting error and high correlation with blood chemistry. The relative uptake rate K-i(r) derived from this model was found to be significantly correlated with direct bilirubin (r= -0.52, P=0.015), prealbumin concentration (r=0.58, P= 0.015), and prothrombin time (r=-0.51, P=0.026). ConclusionIt is feasible to evaluate hepatic function by proper output assumptions. The relative uptake rate has the potential to serve as a biomarker of function. Magn Reson Med 78:1488-1495, 2017. (c) 2016 International Society for Magnetic Resonance in Medicine.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2015]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2015版] 出版当年五年平均[2011-2015] 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者单位: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China.
共同第一作者:
通讯作者:
通讯机构: [1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China. [*1]Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)