Combined application of ultrasound and SPECT/CT has incremental value in detecting parathyroid tissue in SHPT patients

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Capital Medical University, Beijing Friendship Hospital, Department of Nuclear Medicine,95, Yong An Road, Xi Cheng district, 100050 Beijing, People’s Republic of China [2]Capital Medical University, Beijing Friendship Hospital, Radiology Department, 95,Yong An Road, Xi Cheng district, 100050 Beijing, People’s Republic of China
出处:
ISSN:

关键词: SPECT/CT Ultrasound Secondary hyperparathyroidism 99mTc-sestamibi Chronic kidney disease

摘要:
Purpose: The goal of this study is to investigate whether combined application of ultrasound and 99mTc-sestamibi SPECT/CT had the incremental value in accurately detecting parathyroid tissue in patients with SHPT over either method alone. Patients and methods: Sixty patients with SHPT on hemodialysis were evaluated preoperatively with parathyroid 99mTc-sestamibi SPECT/CT scintigraphy and ultrasound prior to parathyroidectomy. The sensitivity, specificity and accuracy of 99mTc-sestamibi SPECT/CT scintigraphy, ultrasound and combined application were determined respectively. Results: The sensitivity, specificity and accuracy of ultrasound were 81% (155/192), 47% (17/36) and 82% (172/228), respectively. The sensitivity, specificity and accuracy of 99mTc-sestamibi SPECT/CT were 85% (163/192), 58% (21/36) and 89% (184/228) respectively. The accuracy of 99mTc-sestamibi SPECT/CT in the diagnosis of parathyroid tissue in patients with SHPT is significantly higher than that of ultrasound. The sensitivity, specificity and accuracy of combined application of ultrasound and 99mTc-sestamibi SPECT/CT were 93% (178/192), 61% (22/36) and 97% (200/228). The sensitivity, specificity and accuracy of combined application of ultrasound and 99mTc-sestamibi SPECT/CT were higher than those of either ultrasound or 99mTc-sestamibi SPECT/CT. Conclusions: The combined application of ultrasound and 99mTc-sestamibi SPECT/CT had incremental value in accurately detecting parathyroid tissue in patients with SHPT over eithermethod alone. (C) 2015 Editions francaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2014]版:
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2014版] 出版当年五年平均[2010-2014] 出版前一年[2013版]

第一作者:
第一作者单位: [1]Capital Medical University, Beijing Friendship Hospital, Department of Nuclear Medicine,95, Yong An Road, Xi Cheng district, 100050 Beijing, People’s Republic of China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)