高级检索
当前位置: 首页 > 详情页

Accuracy assessment of atlantoaxial pedicle screws assisted by a novel drill guide template

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Spinal Surgery, China-Japan Friendship Hospital, Beijing 100029, China [2]Graduate School of Peking Union Medical College, Beijing 100730, China [3]Department of Spinal Surgery, Hong Hui Hospital, Shanxi 710054, China
出处:
ISSN:

关键词: Atlantoaxial instability Pedicle screw Drill guide template Rapid prototyping

摘要:
Posterior atlantoaxial pedicle screw fixation is an effective technique for atlantoaxial instability (AAI). However, because of the complex anatomy of the cranio-cervical junction, it remains challenging to insert atlantoaxial pedicle screw precisely and safely. A novel drill guide template was designed for atlantoaxial pedicle screw placement in this study. The purpose of this study is to quantitatively evaluate the accuracy of atlantoaxial pedicle screw placement using the novel drill guide template. Between June 2014 and September 2015, 32 consecutive patients with AAI were included. Using the Mimics v17.0 and 3-matic v9.0 softwares, a novel drill guide template with two location holes and guide rods was designed. All patients underwent posterior atlantoaxial pedicle screw fixation assisted by the novel drill guide template. After surgery, the entry point and directions of actual and ideal screw trajectories were measured and compared. All patients underwent surgery successfully assisted by the novel drill guide template. A total of 128 atlantoaxial pedicle screws were placed for 32 AAI patients. Postoperative CT scans showed two screws in atlas deviated medially from the pedicle cortex and entered the spinal canal about 1 mm but without symptoms. For both atlas and axis, there were no significant differences in entry point or directions between the ideal and actual screw trajectories (P > 0.05). Significant differences were found in preoperative and postoperative Japanese Orthopaedic Association score and Visual Analogue Score (P < 0.001). It is feasible to use the novel drill guide template for atlantoaxial pedicle screw placement. The accuracy of screw placement assisted by the novel template is high. More studies are needed to confirm the efficacy of this template.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 外科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 骨科 3 区 外科
JCR分区:
出版当年[2014]版:
Q2 ORTHOPEDICS Q2 SURGERY
最新[2023]版:
Q2 ORTHOPEDICS Q2 SURGERY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2014版] 出版当年五年平均[2010-2014] 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Department of Spinal Surgery, China-Japan Friendship Hospital, Beijing 100029, China [2]Graduate School of Peking Union Medical College, Beijing 100730, China
通讯作者:
通讯机构: [1]Department of Spinal Surgery, China-Japan Friendship Hospital, Beijing 100029, China [2]Graduate School of Peking Union Medical College, Beijing 100730, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)