Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Minist Hlth, China Japan Friendship Hosp, Dept Orthoped Surg, Beijing 100029, Peoples R China
出处:
ISSN:

关键词: anatomy atlas posterior arch lateral mass atlantoaxial instability screw fixation

摘要:
Study Design. This study is a result of manual and radiologic measurements of 50 isolated anatomic specimens of C1 and five patients of atlantoaxial instability treated by screw fixation via posterior arch and lateral mass. Objectives. To investigate the feasibility of screw placement via posterior arch and lateral mass in atlas. Summary of Background Data. Several types of posterior approaches have been adopted for stabilization and fusion of atlantoaxial complex. Before this study, Gallie in 1939 gave a report on a posterior wiring technique that depended on a structural bone graft. Since then, double-looped wiring with two bone grafts and Halifax clamp technique had been introduced. A transarticular screw fixation technique was introduced by Magerl and Seeman in 1987, and a C1 lateral mass screw fixation technique was described by Harms in 2001. However, the feasibility of screw fixation in atlas via posterior arch and lateral mass has not been addressed until now. Methods. Fifty dry samples of atlas were measured manually and radiologically with vernier calipers, protractors, and CT. The parameters of posterior arch, lateral mass, vertebral artery groove, axis length of screw path via posterior arch and lateral mass, the entry point, and screw direction were measured. Five patients of atlantoaxial instability were treated with this technique and the radiographs and CT scans were evaluated after surgery. Results. The longest trajectory distance of the screw path was about 30 mm. The outer thickness at the thinnest part of groove was 4.58 mm, and it was found to be <4 mm in four cases (8%). The entry point is 18-20 mm lateral to the midline and 2 mm superior to the inferior border of posterior arch. The direction of screw placement is perpendicular to the coronal plane and about 5 degrees cephalad to the transverse plane. Ten screws via posterior arch and lateral mass were placed properly, without incidence of nerve or blood vessel injury in clinical practice. Conclusion. Atlas is capable for screw fixation via its posterior arch and lateral mass.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2002]版:
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 骨科 3 区 临床神经病学
JCR分区:
出版当年[2001]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2001版] 出版当年五年平均[1997-2001] 出版前一年[2000版] 出版后一年[2002版]

第一作者:
第一作者单位: [1]Minist Hlth, China Japan Friendship Hosp, Dept Orthoped Surg, Beijing 100029, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)