高级检索
当前位置: 首页 > 详情页

Cannulated screw fixation versus plate fixation in treating displaced intra-articular calcaneus fractures: a systematic review and meta-analysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Orthopaedic Surgery, China-Japan Friendship Hospital, No. 2 Yinghua East Road, Chaoyang District, Beijing 100029, China [2]Graduate School of Beijing University of Chinese Medicine, No. 11, Bei San Huan Dong Lu, Chaoyang District, Beijing 100029, China
出处:
ISSN:

关键词: Displaced intra-articular calcaneus fracture Cannulated screw fixation Plate fixation

摘要:
Background Operative treatment has become the current trend for displaced intra-articular calcaneus fracture (DIACF), while using cannulated screw fixation or plate fixation is still controversial for treating DIACF. The purpose of this meta-analysis is to compare the outcome of the two fixation methods. Methods We searched literature comparing cannulated screw fixation and plate fixation from PubMed, Embase, Web of Science, and Cochrane Library. Only randomized controlled trials were included. The outcomes of post-operative function, radiological measurement, time efficiency, and wound complications were pooled in the meta-analysis. Result Seven RCTs with 902 cases of DIACF were included. Pooled results showed the two fixation methods that had similar function satisfactory of AOFAS score (RR = 0.95, 95% CI = [0.83, 1.09], P = 0.47, I-2 = 0%) and Maryland Foot score (RR = 0.93, 95% CI = [0.68, 1.28], P = 0.66, I-2 = 84%). Compared to plate fixation, cannulated screw fixation had better improvement of Bohler's angle (WMD = 0.56, 95% CI = [0.20, 0.91], P = 0.002, I-2 = 34%) and Gissane's angle (WMD = 1.36, 95% CI = [0.56, 2.16], P = 0.0008, I-2 = 7%), better recovery of calcaneal height (WMD = 0.49, 95% CI = [0.02, 0.95], P = 0.04, I-2 = 6%), shorter time to operation (WMD = - 2.91, 95% CI = [- 4.99, - 0.84], P = 0.006, I-2 = 97%), less operation time (WMD = - 21.58, 95% CI = [- 37.31, - 5.85], P = 0.007, I-2 = 98%), reduced length of hospital stay (WMD = - 2.00, 95% CI = [- 3.69, - 0.31], P = 0.02, I-2 = 97%), and less wound complications (RR = 0.16, 95% CI = [0.08, 0.32], P < 0.00001, I-2 = 0%). Conclusion Cannulated screw fixation and plate fixation have similar postoperative functional satisfactory. Cannulated screw fixation is superior to plate fixation in reduction quality, time efficiency, and wound complications.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 骨科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 骨科
JCR分区:
出版当年[2019]版:
Q1 ORTHOPEDICS
最新[2023]版:
Q2 ORTHOPEDICS

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Orthopaedic Surgery, China-Japan Friendship Hospital, No. 2 Yinghua East Road, Chaoyang District, Beijing 100029, China [2]Graduate School of Beijing University of Chinese Medicine, No. 11, Bei San Huan Dong Lu, Chaoyang District, Beijing 100029, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)