Screw fixation via diploic bone paralleling to occiput table: anatomical analysis of a new technique and report of 11 cases

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]China-Japan Friendship Hospital, Department of Orthopedic Surgery, Beijing, China [2]Guangdong Provincial Hospital of TCM, Department of Orthopedic Surgery, Num 111, Da De Road, Guangzhou 510000, China
出处:
ISSN:

关键词: antomy occiput diploic bone occipitocervical instability screw fixation

摘要:
Several types of posterior approaches have been adopted for occipitocervical fusion. Prior to this study, Foerater et al. in 1927 used a fibular strut graft in the site between the occiput and the lower cervical spine to achieve fusion. Since then, various techniques including wrings, Hartshill loop, AO reconstructive plate, and AXIS occipital plate were described and used widely. As far as we know, all these techniques involve the screw placement vertical to the diploic bone; however none has ever addressed the feasibility of screw placement in occiput parallelling to the diploic bone. In our study, 30 dry specimens of human occiputs were measured manually using vernier calipers and protractors. The intradiploic screw was first supposed to be inserted inferiorly to the superior nuchal line (SNL) prominence. The entry point located at the superior edge of the SNL prominence. Afterward, the measurements of extracranial occiput in SNL area on midline and bilateral 15 mm to the midline saggital-cutting planes of the occiput were conducted. The thickness of the occipital bone at the location of SNL prominence, the entry point, the exit point and the screw orientation were measured, respectively. Afterward, 11 patients with craniocervical malformation were treated surgically using this alternative and their X-ray radiographs and CT scans were evaluated postoperatively. The data showed that the occipital at the site of SNL prominence was the thickest. The thickest point was external occipital protuberance (EOP), which was up to 14 mm. The thickness decreased gradually from the site of SNL to the superior border of surgical decompressed area. The actual length of screw channel was about 26 mm. The mean thickness for safe screw insertion ranged from 5.73 to 14.14 mm. A total of 22 intraocciput screws parallel to diploic bone were placed precisely, without injury to the cerebral and inner occipital venous sinus. The results confirm that occiput is available for holding intraocciput screw paralleling to diploic bone.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2006]版:
大类 | 4 区 医学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 骨科 3 区 临床神经病学
JCR分区:
出版当年[2005]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q1 ORTHOPEDICS Q2 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2005版] 出版当年五年平均[2001-2005] 出版前一年[2004版] 出版后一年[2006版]

第一作者:
第一作者单位: [1]China-Japan Friendship Hospital, Department of Orthopedic Surgery, Beijing, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)