高级检索
当前位置: 首页 > 详情页

The accuracy of echocardiography versus surgical and pathological classification of patients with ruptured mitral chordae tendineae: a large study in a Chinese cardiovascular center

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Chinese Acad Med Sci, Cardiovasc Inst, Dept Echocardiog, Beijing 100037, Peoples R China [2]Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China [3]Chinese Acad Med Sci, Cardiovasc Inst, Dept Cardiol, Beijing 100037, Peoples R China [4]Chinese Acad Med Sci, Cardiovasc Inst, Dept Pathol, Beijing 100037, Peoples R China [5]Peking Union Med Coll, Beijing 100037, Peoples R China [6]Capital Med Univ, Beijing Friendship Hosp, Dept Gen Surg, Beijing 100050, Peoples R China
出处:
ISSN:

关键词: ruptured mitral chordae tendineae echocardiography surgery pathology

摘要:
Background: The accuracy of echocardiography versus surgical and pathological classification of patients with ruptured mitral chordae tendineae (RMCT) has not yet been investigated with a large study. Methods: Clinical, hemodynamic, surgical, and pathological findings were reviewed for 242 patients with a preoperative diagnosis of RMCT that required mitral valvular surgery. Subjects were consecutive in-patients at Fuwai Hospital in 2002-2008. Patients were evaluated by thoracic echocardiography (TTE) and transesophageal echocardiography (TEE). RMCT cases were classified by location as anterior or posterior, and classified by degree as partial or complete RMCT, according to surgical findings. RMCT cases were also classified by pathology into four groups: myxomatous degeneration, chronic rheumatic valvulitis (CRV), infective endocarditis and others. Results: Echocardiography showed that most patients had a flail mitral valve, moderate to severe mitral regurgitation, a dilated heart chamber, mild to moderate pulmonary artery hypertension and good heart function. The diagnostic accuracy for RMCT was 96.7% for TTE and 100% for TEE compared with surgical findings. Preliminary experiments demonstrated that the sensitivity and specificity of diagnosing anterior, posterior and partial RMCT were high, but the sensitivity of diagnosing complete RMCT was low. Surgical procedures for RMCT depended on the location of ruptured chordae tendineae, with no relationship between surgical procedure and complete or partial RMCT. The echocardiographic characteristics of RMCT included valvular thickening, extended subvalvular chordae, echo enhancement, abnormal echo or vegetation, combined with aortic valve damage in the four groups classified by pathology. The incidence of extended subvalvular chordae in the myxomatous group was higher than that in the other groups, and valve thickening in combination with AV damage in the CRV group was higher than that in the other groups. Infective endocarditis patients were younger than those in the other groups. Furthermore, compared other groups, the CRV group had a larger left atrium, higher aortic velocity, and a higher pulmonary arterial systolic pressure. Conclusions: Echocardiography is a reliable method for diagnosing RMCT and is useful for classification. Echocardiography can be used to guide surgical procedures and for preliminary determination of RMCT pathological types.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 心脏和心血管系统 4 区 外科
JCR分区:
出版当年[2009]版:
Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
最新[2024]版:
Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Q3 SURGERY

影响因子: 最新[2024版] 最新五年平均[2021-2025] 出版当年[2009版] 出版当年五年平均[2005-2009] 出版前一年[2008版] 出版后一年[2010版]

第一作者:
第一作者单位: [1]Chinese Acad Med Sci, Cardiovasc Inst, Dept Echocardiog, Beijing 100037, Peoples R China [2]Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China [5]Peking Union Med Coll, Beijing 100037, Peoples R China
通讯作者:
通讯机构: [1]Chinese Acad Med Sci, Cardiovasc Inst, Dept Echocardiog, Beijing 100037, Peoples R China [2]Chinese Acad Med Sci, Fuwai Hosp, Beijing 100037, Peoples R China [5]Peking Union Med Coll, Beijing 100037, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:819 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)