高级检索
当前位置: 首页 > 详情页

Validity of asthma control test in chinese patients

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ 中华系列

单位: [1]Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Dept Resp Med, Shanghai 200080, Peoples R China [2]Sino Japan Friendship Hosp, Dept Resp Med, Beijing 100029, Peoples R China [3]Nanjing Med Univ, Affiliated Hosp 1, Dept Resp Med, Nanjing 210029, Peoples R China [4]Gen Hosp Shenyang Mil Command, Dept Resp Med, Shenyang 110015, Peoples R China [5]Beijing Univ, Peoples Hosp, Dept Resp Med, Beijing 100044, Peoples R China [6]Zhejiang Univ, Coll Med, Affiliated Hosp 2, Dept Resp Med, Hangzhou 310006, Peoples R China [7]Shanghai Jiao Tong Univ, Ruijin Hosp, Dept Resp Med, Shanghai 200025, Peoples R China [8]Sichuan Univ, W China Hosp, Dept Resp Med, Chengdu 610041, Peoples R China [9]Guangzhou Inst Res Dis, Dept Resp Med, Guangzhou 510120, Peoples R China [10]Third Mil Med Univ, Xin Qiao Hosp, Dept Resp Med, Chongqing 400037, Peoples R China
出处:
ISSN:

关键词: asthma measurement questionnaires screening validity of results

摘要:
Background So far, in China, there has been no effective or easy procedure to define the control of asthma. This study assesses the validity of Asthma Control Test in Chinese patients. Methods Three questionnaires (Asthma Control Test, Asthma Control Questionnaire and the 30 second asthma test) were administered to 305 asthma patients from 10 teaching hospitals across China. Spirometry was also used. Asthma specialists rated the control of asthma according to patients' symptoms, medications and forced expiratory volume in first second. The patients were divided into noncontrolled group and controlled group according to the specialists' rating. Reliability, empirical validity and screening accuracy were conducted for Asthma Control Test scores. Screening accuracy was compared among 3 questionnaires. The patients' self rating and the specialists' rating were also compared. Results The internal consistency reliability of the 5-item Asthma Control Test was 0.854. The correlation coefficient between Asthma Control Test and the specialists' rating was 0.729, which was higher than other instruments. Asthma Control Test scores discriminated between groups of patients differing in the percent predicted forced expiratory volume in first second (F=26.06, P<0.0001), the specialists' rating of asthma control (F=88.24, P<0.0001) and the Asthma Control Questionnaire scores (F=250.57, P<0.0001). Asthma Control Test showed no significant difference with Asthma Control Questionnaire in the percent correctly classified, while the percent correctly classified by Asthma Control Test was much higher than 30 second asthma test. The patients' self rating was the same as assessment of the specialists (t=0.65, P=0.516). Conclusion The Asthma Control Testis an effective and practicable method for assessing asthma control in China.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2006]版:
大类 | 4 区 医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2005]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2005版] 出版当年五年平均[2001-2005] 出版前一年[2004版] 出版后一年[2006版]

第一作者:
第一作者单位: [1]Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 1, Dept Resp Med, Shanghai 200080, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)