Comparative Analysis of Multiplex Platforms for Detecting Vitreous Biomarkers in Diabetic Retinopathy

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA. [2]Department of Ophthalmology, Zuckerberg San Francisco General Hospital and Trauma Center, San Francisco, CA, USA. [3]Merck & Co., Inc., South San Francisco, CA, USA. [4]Department of Ophthalmology, China-Japan Friendship Hospital, Beijing, China. [5]Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, School of Optometry, Shenzhen University, Shenzhen, China. [6]Department of Ophthalmology, Charoenkrung Pracharak Hospital, Bangkok, Thailand.
出处:
ISSN:

关键词: vitreous cytokine biomarker

摘要:
Purpose: To evaluate the feasibility of using the Proximity Extension Assay (PEA) platform to detect biomarkers in vitreous and to compare the findings with results obtained with an electrochemiluminescent (ECL) sandwich immunoassay. Methods: Vitreous samples from patients with proliferative diabetic retinopathy (PDR) and non-diabetic controls were tested using two different proteomics platforms. Forty-one assays were completed with the ECL platform and 459 with the PEA platform. Spearman's rank correlation coefficient (r(s)) was used to determine the direction and strength of the relationship between protein levels detected by both platforms. Results: Three hundred sixty-six PEA assays detected the tested protein in at least 25% of samples, and the difference in protein abundance between PDR and controls was statistically significant for 262 assays. Seventeen ECL assays yielded a detection rate >= 25%, and the difference in protein concentration between PDR and controls was statistically significant for 13 proteins. There was a subset of proteins that were detected by both platforms, and for those the Spearman's correlation coefficient was higher than 0.8. Conclusions: PEA is suitable for the analysis of vitreous samples, showing a strong correlation with the ECL platform. The detection rate of PEA panels was higher than the panels tested with ECL. The levels of several proinflammatory and angiogenic cytokines were significantly higher in PDR vitreous compared to controls. Translational Relevance: This study provides new information on the yields of small-volume assays that can detect proteins of interest in ocular specimens, and it identifies patterns of cytokine dysregulation in PDR.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 3 区 眼科学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 眼科学
JCR分区:
出版当年[2018]版:
Q2 OPHTHALMOLOGY
最新[2023]版:
Q2 OPHTHALMOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2018版] 出版当年五年平均[2014-2018] 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA. [2]Department of Ophthalmology, Zuckerberg San Francisco General Hospital and Trauma Center, San Francisco, CA, USA.
通讯作者:
通讯机构: [1]Department of Ophthalmology, University of California, San Francisco, San Francisco, CA, USA. [2]Department of Ophthalmology, Zuckerberg San Francisco General Hospital and Trauma Center, San Francisco, CA, USA. [*1]University of California, San Francisco, Department of Ophthalmology, 10 Koret Way, K301, San Francisco, CA 94143-0730, USA
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)