Scan Time Reduction in Intravoxel Incoherent Motion Diffusion-Weighted Imaging and Diffusion Kurtosis Imaging of the Abdominal Organs: Using a Simultaneous Multislice Technique With Different Acceleration Factors

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology,Beijing Friendship Hospital, Capital Medical University [2]Clinical Epidemiology and EBM Unit, Beijing Friendship Hospital, Capital Medical University [3]MR Collaboration, Siemens Healthineers Ltd., Beijing, China [4]MR Application, Siemens Healthineers Ltd., Guangzhou, China.
出处:
ISSN:

关键词: diffusion-weighted imaging simultaneous multislice diffusion-weighted imaging intravoxel incoherent motion diffusion kurtosis imaging abdominal organs

摘要:
Objective To investigate the feasibility of quantitative intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) analyses in the upper abdominal organs by simultaneous multislice diffusion-weighted imaging (SMS-DWI). Subjects and Methods In this prospective study, a total of 32 participants underwent conventional DWI (C-DWI) and SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) in the upper abdomen with multiple b-values (0, 10, 20, 50, 80, 100, 150, 200, 500, 800, 1000, 1500, and 2000 seconds/mm(2)) on a 3 T system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany). Image quality and quantitatively measurements of apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), mean kurtosis (MK), and mean apparent diffusivity (MD) for the liver, pancreas, kidney cortex and medulla, spleen, and erector spine muscle were compared between the 3 sequences. Results The acquisition times for C-DWI, SMS2-DWI, and SMS3-DWI were 10 minutes 57 seconds, 5 minutes 9 seconds, and 3 minutes 54 seconds. For image quality parameters, C-DWI and SMS2-DWI yielded better results than SMS3-DWI (P < 0.05). SMS2-DWI had equivalent IVIM and DKI parameters compared with that of C-DWI (P > 0.05). No statistically significant differences in the ADC, D, f, and MD values between the 3 sequences (P > 0.05) were observed. The D* and MK values of the liver (P = 0.005 and P = 0.012) and pancreas (P = 0.019) between SMS3-DWI and C-DWI were significantly different. Conclusions SMS2-DWI can substantially reduce the scan time while maintaining equivalent IVIM and DKI parameters in the abdominal organs compared with C-DWI.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2019]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Department of Radiology,Beijing Friendship Hospital, Capital Medical University
通讯作者:
通讯机构: [1]Department of Radiology,Beijing Friendship Hospital, Capital Medical University [*1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Rd, Xicheng District, Beijing, 100050, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)