高级检索
当前位置: 首页 > 详情页

The Effect of Degree of Temporal Bone Pneumatization on Sound Transmission of Pulsatile Tinnitus Induced by Sigmoid Sinus Diverticulum and/or Dehiscence: A Clinical and Experimental Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Radiol, Beijing, Peoples R China [2]Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing, Peoples R China [4]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing, Peoples R China
出处:
ISSN:

关键词: Pulsatile tinnitus pneumatization temporal bone sigmoid sinus sound transmission model

摘要:
BACKGROUND: Although many studies have suggested that air cells may play an important role in sigmoid sinus diverticulum and/or dehiscence (SSDD)-induced pulsatile tinnitus (PT), the exact effects remain unclear. This study aims to quantitatively investigate the effect of different degrees of pneumatization of temporal bone on sound transmission from the sigmoid sinus to the tympanic cavity. METHODS: In the clinical study, 25 patients were enrolled to measure the sound intensity and frequency of SSDD-induced PT. In the experimental study, sound inputs at different frequencies at the dehiscent sigmoid plate were measured and compared among realistic object models of different degrees of pneumatization, when sound intensity in the tympanic cavity was fixed as the level of the PT sound intensity sensed by patients. RESULTS: The sound intensity sensed by PT patients was 34.0 +/- 13.0 dB SPL, which represented the sound intensity in the tympanic cavity transmitted from the dehiscent sigmoid plate. In the experimental study, when sound received in the tympanic cavity was fixed at 34 dB SPL, the mean inputs of sound intensity at the dehiscent sigmoid plate were 46.9, 46.2, 45.2, 47.1, 57, 57.4, and 74.1 dB SPL in a hypo-pneumatized model; 42.6, 43, 41.5, 43.2, 47.3, 58.2, and 78.8 dB SPL in a moderately pneumatized model; 52.6, 52.8, 48.1, 61, 64.2, 82.4, and >87.3 dB SPL in a well-pneumatized model; and 47.2, 46.2, 45.4, 49.4, 54.9, 66.6, and 77.7 dB SPL in hyper-pneumatized model, with increased sound frequencies (125-8000 Hz). The mean sound transmission distances were 41.7 mm, 45.2 mm, 47.6 mm, and 48.4 mm in successively better pneumatized models. CONCLUSION: Sound reduces while passing through air cells and attenuation is lowest in the moderately pneumatized temporal bone, followed by the hypo- and hyper-pneumatized temporal bones, and the highest in the well-pneumatized temporal bone. Lower-frequency sound attenuation (<= 1000 Hz) is less than that of higher-frequency sound (>1000 Hz).

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 耳鼻喉科学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 耳鼻喉科学
JCR分区:
出版当年[2019]版:
Q4 OTORHINOLARYNGOLOGY
最新[2023]版:
Q3 OTORHINOLARYNGOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2019版] 出版当年五年平均[2015-2019] 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者单位: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Radiol, Beijing, Peoples R China [2]Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Tongren Hosp, Dept Radiol, Beijing, Peoples R China [2]Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing, Peoples R China [3]Capital Med Univ, Beijing Tongren Hosp, Beijing, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)