高级检索
当前位置: 首页 > 详情页

A geometric alignment for human temporal bone CT images via lateral semicircular canals segmentation

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Faculty of Information Technology, Beijing University of Technology, Beijing, China [2]Department of Radiology, Beijing Friendship Hospital,Capital Medical University, Beijing, China
出处:
ISSN:

关键词: alignment deep learning lateral semicircular canals segmentation temporal bone CT image

摘要:
Due to the different posture of the subject and settings of CT scanners, the CT images of the human temporal bone should be geometrically aligned with multi-planar reconstruction to ensure the symmetry of the bilateral anatomical structure. Manual alignment is a time-consuming task for radiologists and an important pre-processing step for further computer-aided CT analysis. We propose a fully automatic alignment algorithm for temporal bone CT images via Lateral Semicircular Canals (LSCs) segmentation.The LSCs are segmented with our proposed multi-feature fusion network as anchors at first. Then, we define a standard 3D coordinate system and propose an alignment procedure.The experimental results show that our LSC segmentation network achieved a higher segmentation accuracy. The acceptable rate is achieved 85% over 910 raw temporal bone CT sequences. The alignment speed is reduced from 10 minutes by manual to 60s.Aiming at the problem of bilateral asymmetry in the raw temporal bone CT images, we propose an automatic geometric alignment method. Our proposed method can help to perform alignment of temporal bone CT images efficiently. This article is protected by copyright. All rights reserved.This article is protected by copyright. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2020]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]Faculty of Information Technology, Beijing University of Technology, Beijing, China
通讯作者:
通讯机构: [2]Department of Radiology, Beijing Friendship Hospital,Capital Medical University, Beijing, China [*1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)