Subtraction Improves the Accuracy of Coronary CT Angiography in Patients with Severe Calcifications in Identifying Moderate and Severe Stenosis: A Multicenter Study

文献详情

资源类型:
Pubmed体系:
单位: [1]From the Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. [2]Department of Radiology, People's Hospital, Hubei University of Medicine, Shiyan, China. [3]Department of Radiology, Xidian Group Hospital, Xi'an, China. [4]Image Center Shaanxi Provincial People's Hospital, Xi'an, China. [5]Canon Medical Systems (China) CO.,LTD., Building 205, Yard NO.A10, JiuXianQiao North Road, ChaoYang District, 100015, Beijing. [6]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Bejing, China; Department of Radiology, Beijing Chest Hospital, Capital Medical University, Beijing, China. Electronic address: lifang_ty@126.com. [7]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Bejing, China. Electronic address: heyi139@sina.com. [8]From the Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Electronic address: xialiming2017@outlook.com.
出处:
ISSN:

关键词: Cardiac computed tomography coronary artery calcification subtraction stenosis

摘要:
To investigate the diagnostic accuracy of subtraction coronary computed tomographic angiography (CCTAsub) in identifying ≥ 50% and ≥ 70% coronary stenosis in patients with different degrees of calcification.In this study, 180 patients with coronary calcified plaques who underwent both coronary CT angiography and invasive coronary angiography (ICA) were prospectively enrolled at five centers. Patients were divided into three groups according to the Agatston score: group A (low to moderate, < 400), group B (high, 400-999), and group C (very high, ≥ 1000). Diagnostic accuracies estimated by area under the receiver operating characteristic curve (AUC) were compared between conventional CCTA (CCTAcon) and CCTAsub, with ICA as a reference standard.There were 86 patients in group A, 44 in group B, and 50 in group C. In identifying ≥ 70% coronary stenosis, subtraction improved the diagnostic accuracies on a per-segment basis in group B (AUC: 0.80 vs 0.92, p = 0.001) and group C (AUC: 0.75 vs 0.84, p = 0.001) after subtraction. When identifying ≥ 50% coronary stenosis, the per-segment AUC of CCTAsub in group B and C were significantly higher than that in CCTAcon (group B: 0.81 vs 0.92, p < 0.001; group C: 0.77 vs 0.88, p < 0.001). However, no improvement was observed in group A.Subtraction achieved better diagnostic accuracy in patients with Agatston score ≥ 400, both in identifying ≥ 50% and ≥ 70% coronary stenosis, which was instructive for the application of subtraction in clinical practice.Copyright © 2022 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2020]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2020版] 出版当年五年平均[2016-2020] 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者单位: [1]From the Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
通讯作者:
通讯机构: [1]From the Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)