单位:[1]Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, PA 19107 USA[2]Department of Vascular Ultrasound, Shanghai General Hospital, Shanghai, China[3]Department of Ultrasound, Beijing Friendship Hospital, Beijing, China医技科室影像中心超声医学科首都医科大学附属北京友谊医院
Objectives To investigate 3-dimensional subharmonic aided pressure estimation (SHAPE) for measuring intraplaque pressure and the pressure gradient across the plaque cap as novel biomarkers for potentially predicting plaque vulnerability. Methods Twenty-seven rabbits received a high-cholesterol diet for 2 weeks before a balloon catheter injury to denude the endothelium of the aorta, followed by 8 to 10 weeks of the high-cholesterol diet to create arteriosclerotic plaques. SHAPE imagings of the resulting plaques were performed 12, 16, and 20 weeks after injury using a LOGIQ 9 scanner with a 4D10L probe (GE Healthcare, Milwaukee, WI) before and during an infusion of Definity (Lantheus Medical Imaging, North Billerica, MA) and Sonazoid (GE Healthcare, Oslo, Norway). The ratios of the maximum subharmonic magnitudes at baseline and during the infusion were correlated with the intraplaque pressure and pressure gradient across the plaque cap obtained from direct measurements. Results Ten rabbits died prematurely after the balloon injury procedure or due to toxicity from the high-cholesterol diet, whereas 2 rabbits were excluded for other conditions. Five rabbits were scanned in the 12-, 16-, and 20-week groups, respectively. Even after 20 weeks, the plaques that developed were very small (mean +/- SD, 0.9 +/- 0.4 x 0.14 +/- 0.05 cm). Definity performed better than Sonazoid in this application but still only achieved a moderate correlation with pressure across the plaque cap (Definity, r = -0.40; Sonazoid, r = 0.22) and intraplaque pressure (Definity, r = -0.19; Sonazoid, r = -0.11). Conclusions Initial findings from plaque pressure estimation using 3-dimensional SHAPE technique showed only moderate correlations with reference standards, but that may be have been due to weaknesses in the animal model studied.
基金:
National Institutes of HealthUnited States Department of Health & Human ServicesNational Institutes of Health (NIH) - USA [R21 HL119951]
语种:
外文
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类|4 区医学
小类|4 区声学4 区核医学
最新[2025]版:
大类|3 区医学
小类|3 区声学3 区核医学
JCR分区:
出版当年[2017]版:
Q3ACOUSTICSQ3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q2ACOUSTICSQ2RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者单位:[1]Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, PA 19107 USA
通讯作者:
通讯机构:[1]Department of Radiology, Thomas Jefferson University, Philadelphia, Pennsylvania, PA 19107 USA[*1]Department of Radiology, Thomas Jefferson University, 763H Main Building, 132 S 10th St, Philadelphia, PA 19107 USA
推荐引用方式(GB/T 7714):
Nam Kibo,Liu Ji-Bin,Eisenbrey John R.,et al.Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model[J].JOURNAL of ULTRASOUND in MEDICINE.2019,38(7):1865-1873.doi:10.1002/jum.14884.
APA:
Nam, Kibo,Liu, Ji-Bin,Eisenbrey, John R.,Stanczak, Maria,Machado, Priscilla...&Forsberg, Flemming.(2019).Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model.JOURNAL of ULTRASOUND in MEDICINE,38,(7)
MLA:
Nam, Kibo,et al."Three-Dimensional Subharmonic Aided Pressure Estimation for Assessing Arterial Plaques in a Rabbit Model".JOURNAL of ULTRASOUND in MEDICINE 38..7(2019):1865-1873