单位:[1]Department of Acupuncture, China-Japan Friendship Hospital, Beijing 100029, China[2]Department of Orthopedic Surgery, China-Japan Friendship Hospital, Beijing 100029, China[3]Department of Trauma and Orthopedics, Peking University People’s Hospital, South Xizhimen Street No. 11, Xicheng District, Beijing 100044, China[4]Department of Orthopedics, China-Japan Friendship Institute of Clinical Medicine, Peking Union Medical College, Beijing 100029, China
ObjectiveDual-energy CT (DECT) is being widely used in suspected gout patients in recent years. Many clinicians tend to use DECT instead of aspiration biopsy in the diagnosis of gout, but its accuracy has shown controversial results. In this systematic review and meta-analysis, we sought to evaluate the accuracy of DECT in the diagnosis of gout.Materials and methodsWe performed a systematic review of the literature published in Medline, Embase, PubMed, and Cochrane databases. Studies included are all clinical trials of DECT in the diagnosis of gout. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 (QUADAS-2). We recorded sensitivity and specificity of algorithms and calculated positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odd ratio (DOR), and respective confidence intervals (CI). The summary receiver operating characteristic curve (sROC) was drawn to get the Cochran Q-index and the area under the curve (AUC).ResultsSeven studies were included in this review and showed high homogeneity. The analysis results presented the pooled sensitivity was 88% (95% CI 84-90%) and specificity was 90% (95% CI 85-93%). Then, we figured out that the pooled PLR was 8.48 (95% CI 5.89-12.22) and NLR was 0.10 (95% CI 0.04-0.24) respectively. In addition, Cochran-Q was 0.90 and AUC was 0.9565 in sROC curve.ConclusionsDECT showed relatively high sensitivity and specificity in the diagnosis of gout. Synthetically considering these DECT abnormalities could improve the diagnostic sensitivity. More rigorous and standardized studies are still needed to support these findings.
语种:
外文
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2017]版:
大类|4 区医学
小类|4 区骨科4 区核医学
最新[2025]版:
大类|4 区医学
小类|4 区骨科4 区核医学
JCR分区:
出版当年[2016]版:
Q2ORTHOPEDICSQ3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2ORTHOPEDICSQ3RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
第一作者单位:[1]Department of Acupuncture, China-Japan Friendship Hospital, Beijing 100029, China
共同第一作者:
通讯作者:
通讯机构:[2]Department of Orthopedic Surgery, China-Japan Friendship Hospital, Beijing 100029, China[4]Department of Orthopedics, China-Japan Friendship Institute of Clinical Medicine, Peking Union Medical College, Beijing 100029, China
推荐引用方式(GB/T 7714):
Yu Zhange,Mao Tianli,Xu Yaping,et al.Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis[J].SKELETAL RADIOLOGY.2018,47(12):1587-1593.doi:10.1007/s00256-018-2948-y.
APA:
Yu, Zhange,Mao, Tianli,Xu, Yaping,Li, Tengqi,Wang, Yanhua...&Sun, Wei.(2018).Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis.SKELETAL RADIOLOGY,47,(12)
MLA:
Yu, Zhange,et al."Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis".SKELETAL RADIOLOGY 47..12(2018):1587-1593