高级检索
当前位置: 首页 > 详情页

Diagnostic accuracy of dual-energy CT in gout: a systematic review and meta-analysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]Department of Acupuncture, China-Japan Friendship Hospital, Beijing 100029, China [2]Department of Orthopedic Surgery, China-Japan Friendship Hospital, Beijing 100029, China [3]Department of Trauma and Orthopedics, Peking University People’s Hospital, South Xizhimen Street No. 11, Xicheng District, Beijing 100044, China [4]Department of Orthopedics, China-Japan Friendship Institute of Clinical Medicine, Peking Union Medical College, Beijing 100029, China
出处:
ISSN:

关键词: Dual-energy CT Gout Meta-analysis Systematic review Diagnosis

摘要:
ObjectiveDual-energy CT (DECT) is being widely used in suspected gout patients in recent years. Many clinicians tend to use DECT instead of aspiration biopsy in the diagnosis of gout, but its accuracy has shown controversial results. In this systematic review and meta-analysis, we sought to evaluate the accuracy of DECT in the diagnosis of gout.Materials and methodsWe performed a systematic review of the literature published in Medline, Embase, PubMed, and Cochrane databases. Studies included are all clinical trials of DECT in the diagnosis of gout. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies-2 (QUADAS-2). We recorded sensitivity and specificity of algorithms and calculated positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odd ratio (DOR), and respective confidence intervals (CI). The summary receiver operating characteristic curve (sROC) was drawn to get the Cochran Q-index and the area under the curve (AUC).ResultsSeven studies were included in this review and showed high homogeneity. The analysis results presented the pooled sensitivity was 88% (95% CI 84-90%) and specificity was 90% (95% CI 85-93%). Then, we figured out that the pooled PLR was 8.48 (95% CI 5.89-12.22) and NLR was 0.10 (95% CI 0.04-0.24) respectively. In addition, Cochran-Q was 0.90 and AUC was 0.9565 in sROC curve.ConclusionsDECT showed relatively high sensitivity and specificity in the diagnosis of gout. Synthetically considering these DECT abnormalities could improve the diagnostic sensitivity. More rigorous and standardized studies are still needed to support these findings.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 骨科 4 区 核医学
JCR分区:
出版当年[2016]版:
Q2 ORTHOPEDICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 ORTHOPEDICS Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2016版] 出版当年五年平均[2012-2016] 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者单位: [1]Department of Acupuncture, China-Japan Friendship Hospital, Beijing 100029, China
共同第一作者:
通讯作者:
通讯机构: [2]Department of Orthopedic Surgery, China-Japan Friendship Hospital, Beijing 100029, China [4]Department of Orthopedics, China-Japan Friendship Institute of Clinical Medicine, Peking Union Medical College, Beijing 100029, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)