Streptavidin-biotin-peroxidase nanocomplex-amplified microfluidics immunoassays for simultaneous detection of inflammatory biomarkers

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]Analytical & Testing Center of Beijing Normal University, Beijing 100875, China [2]CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China [3]Beijing Institute for Tropical Medicine, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China [4]University of Chinese Academy of Sciences, Beijing 100046, China
出处:
ISSN:

关键词: Microfluidic chips Streptavidin-biotin-peroxidase nanocomplex Procalcitonin Interleukin-6 Signal amplification

摘要:
Simultaneous, sensitive and quantitative detection of biomarkers in infectious disease is crucial for guiding antimicrobial treatment and predicting prognosis. This work reported an ultrasensitive and quantitative microfluidic immunoassay combined with the streptavidin-biotin-peroxidase (SA-B-HRP) nanocomplex-signal amplification system (MIS) to detect two inflammatory biomarkers, procalcitonin (PCT, for discriminating bacterial infections from nonbacterial infections) and interleukin-6 (IL-6, for monitoring the kinetics of infectious disease) simultaneously. The amplification system was based on the one step self-assembly of SA and B-HRP to form the SA-B-HRP nanocomplex, which effectively amplified the chemiluminescent signals. The linear ranges for PCT and IL-6 detections by MIS were 250-1.28 x 10(5) pg mL(-1) and 5-1280 pg mL(-1), and the limit of detection (LOD) were 48.9 pg mL(-1) and 1.0 pg mL(-1), respectively, both of which were significantly improved compared with microfluidic immunoassays without amplification system (MI). More importantly, PCT and IL-6 in human serum could be simultaneously detected in the same run by MIS, which could greatly improve the detection efficiency and reduce the cost. Given the advantages of high sensitivity, multiplex and quantitative detection, MIS could be potentially applied for detection of biomarkers at low concentration in clinical diagnosis. (C) 2017 Elsevier B. V. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 2 区 化学
小类 | 1 区 分析化学
最新[2025]版:
大类 | 2 区 化学
小类 | 2 区 分析化学
JCR分区:
出版当年[2015]版:
Q1 CHEMISTRY, ANALYTICAL
最新[2023]版:
Q1 CHEMISTRY, ANALYTICAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2015版] 出版当年五年平均[2011-2015] 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者单位: [1]Analytical & Testing Center of Beijing Normal University, Beijing 100875, China [2]CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
共同第一作者:
通讯作者:
通讯机构: [2]CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China [4]University of Chinese Academy of Sciences, Beijing 100046, China [*1]CAS Key Laboratory for Biological Effects of Nanomaterials and Nanosafety, CAS Key Laboratory of Standardization and Measurement for Nanotechnology, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing 100190, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)