Computational Fluid Dynamics Simulation of Hemodynamic Alterations in Sigmoid Sinus Diverticulum and Ipsilateral Upstream Sinus Stenosis After Stent Implantation in Patients with Pulsatile Tinnitus

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Interventional Radiography, Beijing Friendship Hospital, Capital Medical University [2]College of Life Science and Bioengineering, Beijing University of Technology, Beijing, People’s Republic of China
出处:
ISSN:

关键词: Computational fluid dynamics Pulsatile tinnitus Sigmoid sinus diverticulum Sinus stenosis Stent implantation

摘要:
OBJECTIVE: To investigate the relationships between upstream venous sinus stenosis and pulsatile tinnitus (PT), and to assess the correlation with diverticulum growth and the effectiveness of stent implantation. METHODS: Patient-specific geometric models were constructed using computed tomography venography images from a patient with PT, with sigmoid sinus diverticulum, and with upstream transverse sinus stenosis, in whom stenting of the upstream sinus stenosis alone achieved complete remission of PT. Computational fluid dynamics simulation based on this patient-specific geometry was performed using commercially available finite element software (ANSYS-14) to qualitatively and quantitatively compare the flow velocity, flow rate, velocity vector, pressure, vorticity, and wall shear stress on the affected side transverse and sigmoid sinuses, before and after stent implantation. RESULTS: Stenting improved the flow direction and magnitude. After stenting, the flow pattern became smoother and more regular. High-speed blood flow at the level of the diverticulum neck was confined to a smaller area, and its direction changed from approximately perpendicular to the diverticular dome to the distal side of the diverticular neck. The diverticulum showed obvious flow reduction, with decreases of 80.7%, 68.7%, 96.1%, and 91.3% in peak velocity, inflow rate, pressure gradient, and peak vorticity, respectively. The abnormally low wall shear stress at the dome of diverticulum was eliminated. CONCLUSIONS: Our findings strongly support a major role of diverticulum stenosis before in PT development and suggest that such stenosis is a causative factor of diverticulum growth. They also confirm the effectiveness of stent implantation for the treatment of PT.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2016]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 外科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外科
JCR分区:
出版当年[2015]版:
Q1 SURGERY Q2 CLINICAL NEUROLOGY
最新[2023]版:
Q2 SURGERY Q3 CLINICAL NEUROLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2015版] 出版当年五年平均[2011-2015] 出版前一年[2014版] 出版后一年[2016版]

第一作者:
第一作者单位: [1]Department of Interventional Radiography, Beijing Friendship Hospital, Capital Medical University
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)