Visualization of microvasculature and thrombi by X-ray phase-contrast computed tomography in hepatocellular carcinoma

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

单位: [1]College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, People’s Republic of China [2]Liver Research Center, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, People’s Republic of China [3]Department of Pathology, Tianjin Medical University General Hospital, Tianjin 300052, People’s Republic of China [4]School of Medical Imaging, Tianjin Medical University, Tianjin 300203, People’s Republic of China.
出处:
ISSN:

关键词: hepatocellular carcinoma (HCC) microvasculature thrombus phase-contrast computed tomography (PCCT)

摘要:
Visualization of the microvascular network and thrombi in the microvasculature is a key step to evaluating the development of tumor growth and metastasis, and influences treatment selection. X-ray phase-contrast computed tomography (PCCT) is a new imaging technique that can detect minute changes of density and reveal soft tissues discrimination at micrometer-scale resolution. In this study, six human resected hepatocellular carcinoma (HCC) tissues were investigated with PCCT. A histological stain was added to estimate the accuracy of PCCT. The results showed that the fine structures of the microvasculature (measuring 30-100 mm) and thrombi in tiny blood vessels were displayed clearly on imaging the HCC tissues by PCCT. Moreover, density distributions of the thrombi were obtained, which could be reliably used to distinguish malignant from benign thrombi in HCC. In conclusion, PCCT can clearly show the three-dimensional subtle structures of HCC that cannot be detected by conventional absorption-based computed tomography and provides a new method for the imageology of HCC.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 2 区 物理
小类 | 2 区 仪器仪表 3 区 光学 3 区 物理:应用
最新[2025]版:
大类 | 3 区 物理与天体物理
小类 | 3 区 仪器仪表 3 区 光学 3 区 物理:应用
JCR分区:
出版当年[2014]版:
Q1 INSTRUMENTS & INSTRUMENTATION Q1 PHYSICS, APPLIED Q1 OPTICS
最新[2023]版:
Q2 INSTRUMENTS & INSTRUMENTATION Q2 OPTICS Q3 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2014版] 出版当年五年平均[2010-2014] 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]College of Biomedical Engineering, Tianjin Medical University, Tianjin 300070, People’s Republic of China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)