高级检索
当前位置: 首页 > 详情页

Glycated albumin may be a choice, but not an alternative marker of glycated hemoglobin for glycemic control assessment in diabetic patients undergoing maintenance hemodialysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE ◇ 统计源期刊 ◇ CSCD-C ◇ 中华系列

单位: [1]Peoples Liberat Army Gen Hosp, Affiliated Hosp 1, Dept Nephrol, Beijing 100048, Peoples R China [2]Peoples Liberat Army Gen Hosp, Inst Nephrol, Beijing 100853, Peoples R China [3]Peoples Liberat Army Gen Hosp, Dept Endocrinol, Beijing 100853, Peoples R China [4]Capital Med Univ, Affiliated Beijing Friendship Hosp, Dept Nephrol, Beijing 100050, Peoples R China [5]Peoples Liberat Army 309th Hosp, Dept Nephrol, Beijing 100091, Peoples R China
出处:
ISSN:

关键词: maintenance hemodialysis diabetes mellitus glycated albumin glycated hemoglobin

摘要:
Background It has been suggested that glycated hemoglobin (HbA1c) underestimate the actual glycemic control levels in maintenance hemodialysis (MHD) patients, because of anemia and the using of erythropoietin (EPO); it was recommended that glycated albumin (GA) should be an alternative marker. Therefore, the assessment performances of glycemic control were compared between GA and HbA1c in this research by referring to mean plasma glucose (MPG) in diabetes mellitus (DM) patients undergoing MHD or not. Methods MPG was calculated according to the data registered at enrollment and follow-up 2 months later and corresponding HbA1c, albumin (ALB), GA, etc. were measured in 280 cases. A case-control study for comparing GA and HbA1c was done among the groups of MHD patients with DM (n=88) and without DM (NDM; n=90), and non-MHD ones with DM (n=102) using MPG for an actual glycemic control standard. Results In these 3 groups, only for DM patients' (whether undergoing MHD or not), GA and HbA1c correlated with MPG significantly (P <0.01). Through linear regression analysis, it could be found that the regression curves of GA almost coincided in MHD and non-MHD patients with DM, because the intercepts (2.418 vs. 2.329) and slopes (0.053 vs. 0.057) were very close to each other. On the contrary, regression curves of HbA1c did not coincide in the two groups, because variance of the slopes (0.036 vs. 0.052) were relatively large. Through comparing receiver operating characteristic (ROC) areas under the curve (AUC), it could be understood that the assessment performances of GA and HbA1c in MHD patients were lower than those in non-MHD ones, and assessment performance of HbA1c in MHD patients was better than GA (P <0.05). In addition, the effects of Hb and EPO dose on HbA1c, or that of ALB on GA were unobvious in our study. Conclusions Actual glycemic control level in MHD patients with DM may be underestimated by HbA1c, and it could be avoided by GA; however, glycemic evaluating performance of HbA1c may be still better than that of GA. Therefore, HbA1c should not be replaced completely although GA can be used as a choice to monitor glycemic level.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2012]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 医学:内科
JCR分区:
出版当年[2011]版:
Q3 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q1 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2011版] 出版当年五年平均[2007-2011] 出版前一年[2010版] 出版后一年[2012版]

第一作者:
第一作者单位: [1]Peoples Liberat Army Gen Hosp, Affiliated Hosp 1, Dept Nephrol, Beijing 100048, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题