摘要:
Background: Following the introduction of modified cellulosic and then synthetic membrane dialyzers, it was realized that the dialyzer bio-incompatibility depends on the membrane composition. We designed a prospective, randomized, cohort study of 6 months to determine several parameters of biocompatibility in maintenance hemodialysis (MHD) patients treated with four different membrane dialyzers. Methods: There were 60 MHD patients enrolled in the study. In baseline, synthetic low-flux dialyzer, polysulfone (PS) membrane was used in all patients for at least 3 months. Then the patients were randomly divided into three groups according to different dialyzer membranes. Synthetic high-flux dialyzer group, ployethersulfone membrane, cellulose triacetate (CTA) high-flux membrane, and synthetic low-flux dialyzer, polymethylmethacrylate (PMMA) membrane were used in 6 months. A new dialyzer was used for each study treatment, and there was no dialyzer reuse. The biocompatibility markers and solutes removal markers were detected repeatedly at different time points. Results: The blood levels of highly sensitive C reactive protein, interleukin (IL)-1 beta beta, and interleukin (IL)-13 showed no difference among different groups at al time points. However, the blood complement levels and white blood cell counts were significantly different among three groups. When the dialyzers changed from PS to PMMA membrane, C3a levels and white blood cell counts changed significantly (p < 0.05). Moreover, the changes of C5a levels were significantly different between group CTA and group PMMA in month 3 (p < 0.05). Conclusion: There were much more differences on bio-incompatibility among different dialyzer membranes.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2010]版:
大类 | 4 区 医学
小类 | 4 区 泌尿学与肾脏学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 泌尿学与肾脏学
JCR分区:
出版当年[2009]版:
Q4 UROLOGY & NEPHROLOGY
最新[2024]版:
Q1 UROLOGY & NEPHROLOGY

影响因子: 最新[2024版] 最新五年平均[2021-2025] 出版当年[2009版] 出版当年五年平均[2005-2009] 出版前一年[2008版] 出版后一年[2010版]

第一作者:
第一作者单位: [1]Capital Med Univ, Dept Nephrol, Beijing Friendship Hosp, Beijing 100050, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:819 更新日期:2025-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)