Multicentre evaluation of the Elecsys(A (R)) hepatitis B surface antigen II assay for detection of HBsAg in comparison with other commercially available assays

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Capital Med Univ, Beijing Friendship Hosp, Beijing 100050, Peoples R China [2]Peking Univ, Peoples Hosp, Inst Hepatol, Beijing 100871, Peoples R China [3]Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Shanghai 200030, Peoples R China [4]Beijing 302 Mil Hosp China, Beijing, Peoples R China [5]Sichuan Univ, W China Hosp Lab, W China Med Sch, Chengdu 610064, Peoples R China [6]Sun Yat Sen Univ, Affiliated Hosp 3, Guangzhou 510275, Guangdong, Peoples R China [7]So Med Univ, Nanfang Hosp, Guangzhou, Guangdong, Peoples R China [8]Fudan Univ, Publ Hlth Clin Ctr, Shanghai 200433, Peoples R China
出处:
ISSN:

关键词: Hepatitis B virus Hepatitis B surface antigen (HBsAg) Immunoassay HBV mutants

摘要:
Screening for hepatitis B surface antigen (HBsAg) demands highly sensitive and specific immunoassays with the ability to detect clinically relevant surface gene mutants-the presence of which is an increasing concern and can compromise test results. The objective of the study was to compare the clinical and technical performance of the fully automated Elecsys HBsAg II assay with other widely used HBsAg immunoassays in China. This was a multicentre study in which eight Chinese laboratories compared the Elecsys HBsAg II assay with the Architect HBsAg assay, AxSYM HBsAg assay, or generic microtitre plate (MTP) enzyme-linked immunosorbent assays (manufactured in China) against preselected samples, including recombinant surface gene mutants, and routine clinical samples. Elecsys HBsAg II was the most sensitive assay for detecting positive results in seroconversion samples: up to 14, 11, and 22 days earlier than the Architect, AxSYM, and MTP HBsAg assays, respectively. It also detected all 211 preselected HBsAg-positive specimens and all 13 recombinant HBsAg mutants; the AxSYM and MTP HBsAg assays failed to detect 3 and 10 mutant samples, respectively. Sensitivity was 100% for Elecsys HBsAg II with routine samples, compared with 99.1, 98.9, and 95.2% for the Architect, AxSYM, and MTP HBsAg assays, respectively. In conclusion, it was demonstrated that the Elecsys HBsAg II assay is suitable for routine HBsAg screening in China.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2008]版:
大类 | 4 区 医学
小类 | 4 区 免疫学 4 区 微生物学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 免疫学 2 区 微生物学
JCR分区:
出版当年[2007]版:
Q3 MICROBIOLOGY Q4 IMMUNOLOGY
最新[2023]版:
Q1 IMMUNOLOGY Q1 MICROBIOLOGY

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2007版] 出版当年五年平均[2003-2007] 出版前一年[2006版] 出版后一年[2008版]

第一作者:
第一作者单位: [1]Capital Med Univ, Beijing Friendship Hosp, Beijing 100050, Peoples R China [*1]Capital Med Univ, Beijing Friendship Hosp, 95 Yong an Rd, Beijing 100050, Peoples R China
通讯作者:
通讯机构: [1]Capital Med Univ, Beijing Friendship Hosp, Beijing 100050, Peoples R China [*1]Capital Med Univ, Beijing Friendship Hosp, 95 Yong an Rd, Beijing 100050, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)