Paediatric CT: the effects of increasing image noise on pulmonary nodule detection

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

单位: [1]UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England [2]Capital Med Univ, Beijing Friendship Hosp, Dept Radiol, Beijing, Peoples R China
出处:
ISSN:

关键词: CT radiation dose pulmonary nodule child

摘要:
Background A radiation dose of any magnitude can produce a detrimental effect manifesting as an increased risk of cancer. Cancer development may be delayed for many years following radiation exposure. Minimizing radiation dose in children is particularly important. However, reducing the dose can reduce image quality and may, therefore, hinder lesion detection. Objective We investigated the effects of reducing the image signal-to-noise ratio (SNR) on CT lung nodule detection for a range of nodule sizes. Materials and methods A simulated nodule was placed at the periphery of the lung on an axial CT slice using image editing software. Multiple copies of the manipulated image were saved with various levels of superimposed noise. The image creation process was repeated for a range of nodule sizes. For a given nodule size, output images were read independently by four Fellows of The Royal College of Radiologists. Results The overall sensitivities in detecting nodules for the SNR ranges 0.8-0.99, 1-1.49, and 1.5-2.35 were 40.5%, 77.3% and 90.3%, respectively, and the specificities were 47.9%, 73.3% and 75%, respectively. The sensitivity for detecting lung nodules increased with nodule size and increasing SNR. There was 100% sensitivity for the detection of nodules of 4-10 mm in diameter at SNRs greater than 1.5. Conclusion Reducing medical radiation doses in children is of paramount importance. For chest CT examinations this may be counterbalanced by reduced sensitivity and specificity combined with an increased uncertainty of pulmonary nodule detection. This study demonstrates that pulmonary nodules of 4 mm and greater in diameter can be detected with 100% sensitivity provided that the perceived image SNR is greater than 1.5.

基金:
语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2007]版:
大类 | 4 区 医学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 儿科 3 区 核医学
JCR分区:
出版当年[2006]版:
Q3 PEDIATRICS Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 PEDIATRICS Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2006版] 出版当年五年平均[2002-2006] 出版前一年[2005版] 出版后一年[2007版]

第一作者:
第一作者单位: [1]UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England [*1]UCL Hosp, Dept Specialist Radiol, Podium Level 2,235 Euston Rd, London NW1 2BU, England
通讯作者:
通讯机构: [1]UCL Hosp, Dept Specialist Radiol, London NW1 2BU, England [*1]UCL Hosp, Dept Specialist Radiol, Podium Level 2,235 Euston Rd, London NW1 2BU, England
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)