高级检索
当前位置: 首页 > 详情页

Noninvasive evaluation of esophageal varices in cirrhotic patients based on spleen hemodynamics: a dual-energy CT study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China [2]Department of Radiology, The Fifth Medical Center of PLA General Hospital, Beijing 100039, China [3]Department of Radiology, The Hospital of Shunyi District Beijing, Beijing 101300, China
出处:
ISSN:

关键词: Dual energy Tomography X-ray computed Liver cirrhosis Portal hypertension Esophageal varices

摘要:
Objective To evaluate noninvasively the severity of esophageal varices (EV) in cirrhotic patients using splenic hemodynamics obtained with dual-energy CT. Methods We retrospectively analyzed 72 cirrhotic patients with EV between December 2018 and June 2019. Patients were divided into three groups: mild (EV1), medium (EV2), or severe (EV3) EV groups based on severity of EV assessed by endoscopy. An additional control group included 20 patients with normal liver CT. All patients underwent contrast-enhanced dual-energy CT. The iodine weight in spleen (IW-S) was calculated as IW-S = IC-S (iodine concentration in spleen) x V-S (spleen volume). Differences between EV and control groups were analyzed using one-way analysis of variance with Welch's correction. Games-Howell test made further pairwise comparison. The diagnostic value of IW-S on high-risk EV (EV2, EV3, or EV1 with red color sign) was evaluated using the ROC curve. p < 0.05 indicated statistical significance. Results The overall difference of IW-S between the control and EV groups was statistically significant (p < 0.001). Patients with more severe EV had higher IW-S values. Pairwise comparisons showed that except for control vs. EV1 groups, the IW-S between any other two groups was significantly different (p < 0.05). With a cutoff value at 1087 mg, the AUC for using IW-S for the detection of high-risk EV was 0.87 (95% CI 0.77 similar to 0.94). Sensitivity and specificity were 84.9% and 84.2%, respectively. Conclusion IW-S obtained with dual-energy CT can noninvasively predict EV severity.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2018版] 出版当年五年平均[2014-2018] 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者单位: [1]Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:816 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)