高级检索
当前位置: 首页 > 详情页

Double-lumen tube intubation using video laryngoscopy causes a milder cardiovascular response compared to classic direct laryngoscopy

| 认领 | 导出 |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

单位: [1]Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
出处:
ISSN:

关键词: Video laryngoscope Double-lumen tube Intubation Hemodynamic response

摘要:
Objective: To determine whether there is a clinically relevant difference between the circulatory responses to double-lumen tube intubation (DLTI) with the GlideScope video laryngoscope versus the Macintosh direct laryngoscope. Methods: Eighty adult patients requiring double-lumen tubes for thoracic surgery were randomly and equally allocatedto either aMacintosh direct laryngoscope group (DL group, n = 40) or a GlideScope video laryngoscope group (GS group, n = 40). DLTIwas performed after airway evaluations and induction of anesthesia. Systolic blood pressure (SBP) and heart rate (HR) were recorded before induction (baseline values), immediately before intubation (post-induction values), at intubation and after intubation. Rate-pressure-product (RPP), and the areas under SBP- and HR-time curve swere calculated. All data obtained by the two devices were compared. Results: After laryngoscope insertion, SBP of DL and GS groups changed significantly differently (13.1% vs. 4.6%, P<0.001), while HR changed similarly (17.2% vs. 14.6%, P = 0.074). One minute after intubation, both SBP and HR significantly increased in both groups (SBP: 11.6% vs. 11.9%; HR: 18.4% vs. 10.8%), but there were no significant differences between the two groups. RPP significantly increased in both groups after laryngoscope insertion (32.6%, P=0.001; 18.2%, P=0.002), and there was a significant difference between the two groups (P=0.001). Throughout intubation, the areas under SBP-time curves had a significant difference between the two groups (P = 0.042), while those under HR-time curves did not differ significantly (P = 0.06). Conclusion: The intubation response was most significant upon laryngoscope insertion during the whole intubation process. The GlideScope video laryngoscope induced milder circulatory fluctuations than the Macintosh direct laryngoscope did, suggesting that DLTI using video laryngoscopy can help reduce the cardiovascular response to intubation.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
JCR分区:
出版当年[2014]版:
Q4 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q2 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均[2021-2025] 出版当年[2014版] 出版当年五年平均[2010-2014] 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者单位: [1]Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing 100050, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:1320 今日访问量:0 总访问量:817 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有:重庆聚合科技有限公司 渝ICP备12007440号-3 地址:重庆市两江新区泰山大道西段8号坤恩国际商务中心16层(401121)